Specifications
UVP ... (800) 452-6788 | (909) 946-3197 | +44(0)1223-420022 | UVP.com UVP ... (800) 452-6788 | (909) 946-3197 | +44(0)1223-420022 | UVP.com
PCR systems use shortwave ultraviolet to control PCR
contamination. In addition to standard UV Sterilizing PCR
models, HEPA/UV PCR systems with four-stage filters are
available. Both the HEPA/UV and the
standard UV Sterilizing PCR Systems
are available in two sizes, Cabinet and
Workstation. The Cabinet has a small-
er footprint than the Workstation.
All PCR equipment include the
following features:
UV PCR Ordering Information
UV Sterilizing PCR
Cabinet*
UV2 Sterilizing PCR
Cabinet*
UV Sterilizing PCR
Workstation*
UV2 Sterilizing PCR
Workstation*
95-0437-01 (115V)
95-0437-02 (230V) UK
95-0437-04 (230V) Euro
95-0436-01 (115V)
95-0436-02 (230V) UK
95-0436-04 (230V) Euro
95-0367-01 (115V)
95-0367-02 (230V) UK
95-0367-04 (230V) Euro
95-0439-01 (115V)
95-0439-02 (230V) UK
95-0439-04 (230V) Euro
Light Sources
254nm UV:
Chamber
White Light:
Chamber
Light Sources
254nm UV:
Chamber
UV/air circulator
White Light:
Chamber
Light Sources
254nm UV:
Chamber
White Light:
Chamber
Light Sources
254nm UV:
Chamber
UV/air circulator
White Light:
Chamber
Two power outlets
Two small shelves
UV Timer (<
30 min.)
Antimicrobial coated
stainless steel
Acrylic panels block
below 400nm
Two power outlets
Two small shelves
UV Timer (<
30 min.)
Antimicrobial coated
stainless steel
Acrylic panels block
below 400nm
Four power outlets
Two shelves
UV Timer (<
30 min.)
Antimicrobial coated
stainless steel
Acrylic panels block
below 400nm
Four power outlets
Two shelves
UV Timer (<
30 min.)
Antimicrobial coated
stainless steel
Acrylic panels block
below 400nm
Dimensions HWD:
28.7 x 21.4 x 24 in.
(729 x 544 x 610mm)
Dimensions HWD:
28.7 x 21.4 x 24 in.
(729 x 544 x 610mm)
Dimensions HWD:
28.7 x 29 x 24 in.
(729 x 737 x 610mm)
Dimensions HWD:
28.7 x 29 x 24 in.
(729 x 737 x 610mm)
*Assembly required.
UV Sterilization. All UVP PCR systems create an ideal
environment for PCR preparation by reducing the chance of
sample contamination. Control potential PCR contamination
with 254nm UV tubes built into the chamber. UV2 models
feature both overhead UV and built-in UV air recirculator for
continuous sterilization.
Antimicrobial Protection. Additional contamination control is
provided with a uniquely coated stainless steel design that
maintains antimicrobial efficacy. The easy clean, durable
coating material contains silver ions, a safe and natural
antimicrobial agent for continuous antimicrobial protection.
PCR Table
98-0077-01
Optional PCR table
features two rigid and
two adjustable, lock-
ing casters. Anti-
microbial coated
stainless steel
reduces bacterial
growth. The table
accommodates all
UVP PCR cabinets
and workstations.
UV/Air Circulator Module (for 95-0367-xx only)
95-0157-01 115V
95-0157-02 230V
UV PCR Workstation shown. Smaller footprint, UV PCR
Cabinet also available.
Built-in shortwave (254nm) UV
tubes for deactivation of DNA between experiments
30-minute timer sterilizes apparatus and chamber with
the shortwave UV between experiments
Safety shut-off switch automatically turns the ultraviolet
light off when the door is opened
Keylock prevents accidental exposure of samples to UV
Easy-clean antimicrobial coating on the stainless steel
resists bacteria growth
Hinged door flips up for easy access to the work area
Built-in power outlets for operation of equipment inside the
PCR work area
Two shelves for placement of small equipment
Dual acrylic panels block UV below 400nm
Shortwave
254nm UV and
antimicrobial
coated stainless
steel to control
contamination
P
P
PP
C
C
CC
R
R
RR
S
S
SS
y
y
yy
s
s
ss
t
t
tt
e
e
ee
m
m
mm
s
s
ss
PCR SYSTEMS
UV PCR Cabinets and Workstations
UU
UU
ll
ll
tt
tt
rr
rr
aa
aa
vv
vv
ii
ii
oo
oo
ll
ll
ee
ee
tt
tt
LL
LL
aa
aa
mm
mm
pp
pp
ss
ss
For sterilization applications, the XX Series
Mineralight shortwave bench lamps use 254nm UV
radiation as a reliable and effective tool for steriliza-
tion and sanitation applications in hospitals, laborato-
ries, pharmaceutical companies and clinics. Work
areas and equipment can become contaminated
with bacteria which may be passed via the air or by
hand, infecting research projects and workers.
Once the researcher knows the micro-organism to be
destroyed and how much energy is required, divide
the energy required (in units mW/cm
2
at 12 in. for the
XX-15S) to calculate the total exposure time required
to do the job.
Place the lamp in an upward facing position for
purifying air or facing downward for sanitizing
work surfaces
Shortwave (254nm) ultraviolet can kill up to 99%
bacteria, mold spores, yeast and germs
The UV intensity can be increased by bringing
the lamp closer to object being sterilized
Brackets are included for hanging the lamp to
reduce space required on laboratory benchtops
Lamps are manufactured with a durable alu-
minum housing and scratch-resistant powder
paint finish
Dimensions:
XX-15S: 19.75L x 6W x 4.25H in. (502 x 152 x108mm)
Weight: 5 lb (2.3kg)
XX-20S: 24L x 6W x 4.25H in. (610 x 152 x 108mm)
Weight: 10 lb (4.5 kg)
XX-40S: 49.6L x 6W x 4.25H in. (1260 x 152 x 108mm)
Weight: 20 lb (9.0 kg)
UV Bench Lamps are available in 15-watt, 20-watt and 40-watt.
Select from several wavelengths for UV illumination in many
industrial and laboratory applications
Exposure Stand shelf is
adjustable to different levels
for repeatable exposure of
samples.
XX-15 lamp models can be attached to the Exposure
Stand for exposure of materials to ultraviolet
The shelf is adjustable to set distances from the
ultraviolet source
Stand Dimensions:
20W x 6D x 13H in.
(508 x 152 x 330mm)
Weight: 8 lb (3.6 kg)
Accessories
An optional UV transmitting filter for the XX-15S allows use
for fluorescence applications.
Filter
Covers and
clear covers
can be
attached to
the XX-15S
lamp (left).
26 11
Ordering Information
XX-15S
254nm UV, 15-watt
Replacement Tube
95-0042-05 (115V)
95-0042-09 (230V)
34-0008-01
XX-15M
302nm UV, 15-watt
Replacement Tube
95-0042-08 (115V)
95-0042-15 (230V)
34-0039-01
XX-15L
365nm UV, 15-watt
Replacement Tube
95-0042-07 (115V)
95-0042-13 (230V)
34-0009-02
XX-15 BLB
365nm BLB UV, 15-watt
Replacement Tube
95-0042-06 (115V)
95-0042-11 (230V)
34-0017-01
XX-20S
254nm, 20-watt
Replacement Tube
95-0045-07 (115V)
95-0045-08 (230V)
34-0067-01
XX-20 BLB
365nm BLB UV, 20-watt
Replacement Tube
95-0045-04 (115V)
95-0045-05 (230V)
34-0068-01
XX-40S
254nm, 40-watt
Replacement Tube
95-0043-07 (115V)
95-0043-08 (230V)
34-0067-02
XX-40 BLB
365nm BLB UV, 40-watt
Replacement Tube
95-0043-04 (115V)
95-0043-05 (230V)
34-0068-02
Cover, clear (XX-15 BLB) 19-0140-01
Filter (XX-15S) 38-0172-02
XX-15 Stand 18-0062-01
catalog spreads final 7 09 09.qxp 7/15/2009 4:25 PM Page 11