Data Sheet
Technical Datasheet
TD-T-8959_98375 uvex 4B-GB
SBU-W-PGM-T
Disposable Protection Clothing
UVEX ARBEITSSCHUTZ GMBH, Würzburger Str. 181-189, D-90766 Fürth
Performance data*:
* Tested under laboratory conditions: temperature (20 ± 2)°C and (65 ± 5)% relative humidity
*² Particle size according to details on testing substance as mentioned in EN136, 8.16.3.2.2: "particle size description must be 0,02µm - 2µm EAD with a MMD of 0,6µm“
Version: 29/10/2018 3
unit
Ergebnis Bereich /
result
Klasse
/ class
EN 14126 Barrier to infective agents
ISO 16603: Determination of the resistance of protective
clothing materials to penetration by blood and body fluids —
Test method using synthetic blood
kPa 6 of 6
ISO 16604: Determination of resistance of protective clothing
materials to penetration by blood-borne pathogens — Test
method using Phi-X174 bacteriophage
kPa 6 of 6
EN ISO 22610: Resistance to wet bacterial penetration
(mechanical contact)
min 6 of 6
ISO/DIS 22611: Resistance to penetration by biologically
contaminated liquids
log R 3 of 3
ISO/DIS 22612: Resistance to penetration by biologically
contaminated dust
log cfu 3 of 3
EN 14126: attachment A Resistance to penetration by
infective agents due to mechanical contact with substances
contraining contaminated liquids
min -
Various additional Tests
EN 20811 hydrostatic head (water pressure test) cm 80
EN 31092 / ISO 11092 Water vapour resistance R
et
m²*Pa/W ≤ 20 3 of 3
EN ISO 9237 air permeability l/(m²*s)
UPF Material 50+ -
DIN 32781 protection against pesticides
Brand Name / ZA-No. - Manufacturer
U46-D-Fluid / 0941-00 - BASF
% n.d. -
Pirimor Granulat / 2470-00 - Syngenta % n.d. -
Amistar / 5090-00 - Syngenta % n.d. -
Betanal Expert / 4991-00 - Bayer CropScience % n.d. -
Folicur / 4028-0 - Bayer CropScience % n.d. -