User's Manual

manual opration
1.Plug in the cart and turn on power switch
. Rotate the rotary dial to choose sanitizing cycle 5min10min20min (default
option is OFF). 90S countdown is started and shown on display. At the end of 90S, chime sound warns users leave sanitizing
area (three,Di Di Di)
2.During the 90S countdown, PIR sensor doesn’t active. After 90s end, the cart enter sanitizing cycle, at the meantime, PIR
sensor starts to work. When PIR sensor detected someone is still in the sanitizing area, UVC lamp will turn off automatically.
When motion is no longer detected, UVC lamp will not turn on to proceed work automatically. If users want to restart the cart,
they need to turn off the power switch then turn on the power switch to restart it manually;
3.IF the cart with WIFI,Plug in the cart and turn on power switch
. Press pairing button 5S till blue pairing indicator
light
flash quickly,after successful connection, the indicator light will always be on . Open phone and enter APP UI
users can set the time. When PIR sensor detected motion during sanitizing cycle, UVC lamp will turn off automatically. When
motion is no longer detected, UVC lamp will not turn on to proceed work automatically. Users need to click on/off button
on APP if they want to restart the cart( there is no 90S countdown). When users don't know whose phone connected to
the device,Long press the press pairing button to remove the device
III. Motion Sensor Operation(If the lamp with Motion Sensor):
1. Turn on the UV lamp, select the disinfection time and left the room, after 90 seconds ,alarming(Di….Di…Di….), the UV lamps will switch on
automatically, the motion sensor will activated.
2. It will turn off when it detects that someone moving around . If users want to restart the cart, they need to turn off the power switch
then turn on the power switch to restart it manually
IV. Note:
1. The surface of the lamp should be kept clean.
2. The lamp is fragile. Please handle it with care.
3. A room should be ventilated after UV disinfection, and people are suggested to enter the room 30-40minutes later.
V. Warning
SAVE THESE INSTRUCTIONS
Beam angle
360°
Weight
28.5kg
Life
60000Hrs
IP level
IP20
UV radiation intensity(1m)
1300uW/cm² Color
Black
Safety classification
Class
Dimensions(L*W*H)(mm
L940*W500*H1540mm