Technical data
Table Of Contents
- iAN-02EX Release 1.0 Administrator Manual Issue 1.7
- Contents
- List of Tables
- List of Figures
- About This Guide
- Overview
- Hardware Installation
- Technical Specification
- Configuring TCP/IP Protocol
- Configuration
- Troubleshooting
- iAN-02EX Provisioning Methodology
- Provisioning overview
- Provisioning Features
- Provisioning Process rules
- Auto-Configuration
- Brief description on HTTP/TFTP Provisioning servers
- HTTP Provisioning servers
- Selection Prority for HTTP or TFTP servers
- Frequency of Upgrade
- Provisioning Server configuration files
- File format of the configuration File
- Encryption Engine
- Firmware Upgrade
- Provisioning Default Values
- UTStarcom, Provisioning Default Flag Values
- Sample Provisioning Flow Behavior
- Provisioning Flow
- Default Setting & Value
- iAN-02EX SNMP MIB Reference
- Upgrade Procedure

MIB Scalar Objects
137
Part Number UTSI-NJTC-200323150117
iAN-02EX
June 2005
Administrator Manual
rgMgtNtpExpires
1.3.6.1.4.1.4684.5.4.7.17.0
read-write current
The period(in seconds) of retrieving time from NTP server. Integer32
rgMgtNtpSync
1.3.6.1.4.1.4684.5.4.7.18.0
read-write current
Synchronize local time with ntp server. INTEGER
■
on(1)
■
off(2)
default = off
rgMgtSyslogServerAddress
1.3.6.1.4.1.4684.5.4.7.19.0
read-write current
The network IP address of the syslog server. IpAddress
rgMgtSyslogServerPort
1.3.6.1.4.1.4684.5.4.7.20.0
read-write current
The port number of the syslog server. INTEGER (1..65536)
rgMgtVoipStunNatAddress
1.3.6.1.4.1.4684.5.4.7.21.0
read-write current
The network IP address of the NAT firewall. Should be
specified if this device is located behind a NAT firewall. The
NAT firewall should also activate port mapping or DMZ
funtions to forward incoming voip signaling packet and RTP
packets to this device. Make sure the STUN(Simple
Traversal of User Datagram) server address is 0 if you want
to specify nataddress by yourself. If the IP address of the
NAT firewall is unknown, specify STUN server to determine
it automatically.
IpAddress
rgMgtVoipStunServerIp
1.3.6.1.4.1.4684.5.4.7.22.0
read-write current
The network IP address of STUN(Simple Traversal of User
Datagram) server. It is used to detecting the IP address of
the NAT firewall. If this function is enabled, after detecting
the IP address of the NAT firewall, 'nataddress' will be
changed automatically.
IpAddress
rgMgtVoipStunServerPort
1.3.6.1.4.1.4684.5.4.7.23.0
read-write current
The port number of the STUN server. INTEGER (1..65536)
rgMgtVoipStunLocalport
1.3.6.1.4.1.4684.5.4.7.24.0
read-write current
The local listening port number of the STUN client. INTEGER (1..65536)
rgMgtVoipStunExpires
1.3.6.1.4.1.4684.5.4.7.25.0
read-write current
The period(in seconds) of sending STUN message to STUN
server.
Integer32
rgEmsSnmpGetCommunity
1.3.6.1.4.1.4684.5.4.8.1.0
read-write current
The snmp get community name of system. DisplayString (0..255)
rgEmsSnmpSetCommunity
1.3.6.1.4.1.4684.5.4.8.2.0
read-write current
The snmp set community name of system. DisplayString (0..255)
Table 47
MIB Scalar Objects Table
Node / OID Description Settings