Install Manual

RPC/RP Manual 200mW RP Installation
25July2000 WLL-200mW-RP-IN-1.0
25
2.8 Waterproof Treatment of the Line Cables
1. Make sure that the cables are properly wired.
2. To shrink the cables, put your finger into the loop of the spiral core and pull it,
as displayed in Figure 25. Pull it around the cable, making sure that the spiral
core will not get tangled up with the cables. When the spiral core is pulled out
a contraction tube sticks fast around the cables.
3. Make sure that the spiral core is removed completely.
Figure 25: Shrinking the Cables