User Manual

RPC/RP Manual RPC/RP Configuration
19June2000 WLL-RPC/RP-IN/UM-1.0
4-
53
MSB LSB
Bit 8 7 6 5 4 3 2 1
0 0 0 0 X X X X
Bit 1 corresponds to the installation status of E1-IF#1
Bit 2 corresponds to the installation status of E1-IF#2
Bit 3 corresponds to the installation status of E1-IF#3
Bit 4 corresponds to the installation status of E1-IF#4
Installation status: Installed à 1
Not installed à 0
Set "installed" or "not installed" for each E1-IF according to the E1-IF
installation plan. Set "installed" for all E1-IF’s for future expansion.
E1 interface install setting (2) is reserved for system expansion.
LCCH frequency (Control carrier frequency)
This item is used to set LCCH frequency of the system. The system can
use one carrier from No. 1 to No. 77. This value is assigned by the
operator or Government. For instance, if LCCH frequency is No.71, the
setting value is 71 (HEX: 4D). In one-service area LCCH frequency and
Operator ID must be the same for all RPs and RPCs.
Channel frequency use control (1-8), (9-16) ….. (73-77)
The item is used to set the availability of Traffic channels. Every channel
frequency (carrier number 1 through 77) can be set "available" or
"unavailable". For Channel frequency use control (1-8) the values are set
as follows:
MSB LSB
Bit 8 7 6 5 4 3 2 1
X X X X X X X X
Bit 1 corresponds to Channel frequency No.1 (carrier No.1)
Bit 2 corresponds to Channel frequency No.2 (carrier No.2)
................
Bit 7 corresponds to Channel frequency No. 7 (carrier No.7)
Bit 8 corresponds to Channel frequency No. 8 (carrier No.8)
Setting value: Available à 1