Operator ID Code: MSB is always set to "1". The remaining 8 bits are
used for Operator ID. The Operator ID’s of all RPs that connect to the
same RPC take the same value, and the value is equal to the setting value
of this data field.
Paging Area Number refers to the area where the call is broadcast for the
FSU or PS that has location registration for that area. In effect, PS doesn't
need to request location registration while it stays inside the area, even if it
switches RPs. The Paging Area Number of all RPs that connect to the
same RPC takes the same value, and the value is equal to the setting value
of this data field.
Additional ID (11bits) of this data field is set from "00000000000" to
"11111100000". The upper 6 bits of the Additional ID of the RPs that
connect to the same RPC take the same value, and the value is equal to the
setting value of this data field.
The first 37 bits of this Call Discrimination Code correspond to the RP-ID
(CS-ID) of each RP that connects to the same RPC, and the value of the 37
bits is the same for all the RPs which connect to the same RPC. The last 5
bits are unique for each RP under the same RPC, as illustrated below:
RP #
RP #1 RP #2 RP #3 RP #4 …… RP #32
Last 5 bits
00000 00001 00010 00011 …… 11111
For instance, when the field data (48bits) of the Call Discrimination Code
are 9E 00 00 00 03 80 (HEX), the RP-ID (42 bits) of RP#4 is as follows:
1001 1110 0000 0000 0000 0000 0000 0000 0000 0011 11 (Binary)
Operator ID: 1001 1110 0 (Binary)
Paging area: 000 0000 0000 0000 0000 000 (Binary)
Additional ID: 0 0000 0011 11 (Binary)
F NOTE: The RP-ID that is described in this section is used between RP/RPC and
FSU/PS. The RP-ID is also defined between WLL/V5WLL and RPC but the
length is 48 bits. This RP-ID is generated by the RP-ID of the air interface but is
not the same as the RP-ID of the air interface. RPC can translate between the
RP-ID of the WLL/V5WLL/RPC and the RP-ID of the air interface..
E1 interface install setting
This item is used to configure E1 interface install setting (1), as described
below: