User Manual
RPC/RP Configuration RPC/RP Manual
WLL-RPC/RP-IN/UM-1.0 19June2000
4-
50
2. This window is for the configuration of Group Control. Group Control
maximizes the number of channels available for traffic by allowing one
control channel to control up to 8 RPs (up to 31 traffic channels). A group
can be set up only within two adjacent RP interface boards. Group members
must be within the two RP Interface boards. For each RP, enter the group
number and designate the master. In the above window, 7 RPs on RP
Interface card 5 and 6 are in group 17 with the master RP designated as RP
number 17. The master RP must be the RP with the lowest RP number in the
group. The RPs that are not in group control must be designated as their own
masters and have their own group numbers, as is the case for RP# 21 in the
above figure.
4.3.8.3 Service Data 3: System Parameters
The third Edit of Service Data window contains system parameters. It is not
necessary to administer the parameters, as they are set at the factory. Users can
only change the relevant values for the parameters. Click on Next or Switch 3 to
open the Edit of Service Data 3 window, as shown in the figure below.
Figure 4-57: Edit of Service Data 3 Window