1. To view the log of the Alarm History, select the Alarm History option from
the Status main menu. The Alarm History window appears as shown in the
figure below. Another way to open the window is to click the Fault History
button.
Figure 4-64: Alarm History Window
F NOTE: This log has a capacity of storing 127 messages. When this limit is
reached, the oldest message is deleted when the newest one is added.
2. Click Update to display the historical information. To clear the present alarm
history, click Clear. The contents of this window can be saved to a file for
further analysis. Click the Save button and specify a file name.
3. Click Close to close this window.
4.5 Reset RPC
When an RPC or its other components experience trouble and the problem cannot
be solved, it may be necessary to reset the component. Use the following
procedures to reset an E1 interface, an RP interface, an RP, or an RPC.
F WARNING: Do not directly reset a unit in operation since this will cause active
subscriber calls to be dropped. Before resetting a unit, block the unit temporarily
by resorting to the Configuration à Unit Control à Blockade option. Check
the Channel Status to verify that there are no active calls. Click the Channel