User Manual

RPC/RP Manual RP Installation
19June2000 WLL-RPC/RP-IN/UM-1.0
3-
5
Figure 3-4: Accommodated Subscribers per RP in Group and Non-group Control
The recommended installation design for RPs is as follows:
A zone of sparse subscribers should be covered by non-group controlled
RPs.
A zone of dense subscribes should be covered by group-controlled RPs.
The number of accommodated subscribers is the greatest when all of the RPs
connected to an RPC are configured in the group control mode. In this case (with
4 RPs in each group), the number of service zones is eight (32÷4), and the
maximum number of subscribers is 1,056 (132x8). Each Group Control zone
supplies 15 traffic channels. Eight zones require 120 channels (15x8) provided by
4 E1 lines with 30 channels each.
3.1.2 Cell Overlap
Maximum service results are achieved when the RP coverage area is strategically
installed in a Cell Overlap Capacity.