User Manual
RP Installation RPC/RP Manual
WLL-RPC/RP-IN/UM-1.0 19June2000
3-
4
Figure 3-3: Group Control RPs
In the group control mode, the number of accommodated subscribers in the group
control coverage zone is calculated in accordance with the erlang theory as
follows (with 4 RPs in the group):
• Erlang per zone (15 T-chs, GOS=5%) = 10.663 erlang
• Subscribers (FSUs or PSs) (10.663÷.08) = 132 subscribers
The comparison for the number of accommodated subscribers between the group
controlled RPs and the single RP is shown in Figure 3-4.
F NOTE: Figure 3-4 represents the group control with 4 RPs. Each group can
have a maximum of 8 RPs.