User Manual

RPC/RP Configuration RPC/RP Manual
WLL-RPC/RP-IN/UM-1.0 19June2000
4-
44
Field Name Description
SDM Selection Select one of the two operation data systems: SDM-
#N or SDM-#E. Any one can be ACT or SBY.
N System One of the two operation data systems
E System One of the two operation data systems
Table 4-11: Read System Service Data Window Field Description
2. Make a selection in the SDM Selection block and click OK.
3. The following window appears, prompting for the folder and file name in
which to save the service data after reading out.
Figure 4-49: Save File after Reading Service Data Window
4. Select a folder and enter a file name. The file name must have the extension
of .dat or .eep. In addition, the file name must start with W and have 8
letters. Then click Save.
5. A confirmation box appears. Click Yes to start the reading of the data.
4.3.6 Write Data
Use the procedure in this section to load the operation data to both the SDMs
while the RPC is operating. As for this command, automatic switching is not
supported. After the implementation of the command, the RPC still runs based on