User Manual

RPC/RP Manual RPC/RP Configuration
19June2000 WLL-RPC/RP-IN/UM-1.0
4-
23
Field Name Description
ACT The active SDM or PDM system for RPC running
Program System PDM system. There are two plane memory areas for the
program data: N and E. Any one can be active or standby.
SDM System SDM system. There are two plane memory areas for the
operation data: N and E. Any one can be active or standby.
Update Retrieve the latest mode information and display the time
when the mode information is updated.
Mode Display mode information for the current RPC, such as,
master/slave status, synchronization status, transmission
status, etc. The following rows describe various mode
displays.
Mode Display Description
Master Master RPC - the RPC that generates the air frame
synchronization signal.
Slave Slave RPC - the RPC that receives the air frame
synchronization signal.
Sync. signal Trans. The RPC transmits the synchronization signal to the slave
RPC or the next slave RPC.
Sync. signal Stop The RPC doesn’t transmit the synchronization signal to the
slave RPC or the next slave RPC.
Sync. between RPC Sync. The slave RPC synchronizes to the upstream RPC.
Sync. between RPC Async. The slave RPC doesn’t synchronize to the upstream RPC.
Table 4-2: RPC Status Window Field Description
2. This window is for view only. In this instance, there is no special meaning for
N or E. It simply displays which system is active. Refer to Section 4.3 for the
description of the N and E systems.
4.2.4.2 RP Status
Use the RP Status option to monitor the operation status of individual RPs and to
verify any change made to the RP configuration and setting.
1. To access the RP Status window, click Status, then Status, and then RPs.
Another way to display the window is to click the RP Status button. The RP
status is displayed on the Status View window, as shown in the figure below.