User Manual

Fixed Subscriber Unit Installation Manual Installation Instructions
Release 1.00 10/03/97
Airstar-Wireless Local Loop
4-23
WARNING : DEPENDING ON LOCATION, IT MAY BE NECESSARY TO
GROUND THE ANTENNA TO PREVENT DAMAGE BY
LIGHTNING. REFER TO THE FIGURE BELOW FOR A
DIAGRAM OF THE EARTH CABLE CONNECTION.
AWG 12
copper wire
insulated
6 inches above ground
ground line
5 ft. by .5 inch
copper clad rod
Terminal Lug
Figure 4-9 : Earth Cable Connection
6. Attach a terminal lug to the lower bracket screw and tighten
screw.
7. Plug insulated copper wire into the terminal lug and use the
terminal lug crimper to affix the copper wire to the terminal
lug.
8. Attach the other end of the copper wire to a copper clad rod
as shown in the figure above.