Instructions / Assembly
MASTER CONTRACT: 263865
REPORT: 70030918
PROJECT: 80056731
Page No: 47
Date Issued: September 30, 2020
DQD 507.10 Rev 2020-07-02 © 2020 CSA Group. All rights reserved.
5.23 Burn hazard potential – NA, no glass panels
5.24 Marking material adhesion and legibility – Waived, use certified type
Construction Review:
Construction review performed with satisfactory results.
Project 80056731
The following tests were conducted in:
CCIC-CSA International Certification Co., Ltd.
No. 10, Ke Yan Road
Science Park
Guangzhou 510663
China
ANSI Z21.97-2017 / CSA 2.41-2017 Outdoor Decorative Gas Appliances
Update report no.70030918 to cover alternate construction, rename listed model GFT-68069F as GFT-30801, and
add new models GFT-61464, GFT-31269B, GFT-31269, GFT-61358, GFT-10505A, GFT051057T, GFT-
30801B, GFT-31741, GFT-31604, GFT-31756, GFT-61623, GFT-10685, GFT-31555, GFT-10674C, GFT-
31757, GFT-68043R, GFT-10714C, GFT-10715B. Glass rock is also used as burning media on models with
round burner tray.
The construction of round type burner tray used in this report is updated. The depth of the tray need to be reduce
from 65mm to 45mm, and move the heat shield from inner side to outer side of the burner tray bottom. On the old
design, the burner is mounted on the heat shield, and the clearance between heat shield and burner tray bottom is
20mm. Thus on the new design, the burner remain the same height level as before.
The new models are extended from certified models of report 70090318, except that the appearances are different
and no affects on test result. See figure no.117 to 1189 for detail.
Representative model GFT-31741 with new designed round type burner tray was selected for below test and
satisfactory result was found:
Section 4 Construction
Section 5 Performance
5.1 General
5.2 Test Gases
5.3 Test pressures and burner adjustments
5.4 Combustion
5.5 Burner operating characteristics – Extended from report no.70030918
5.6 Pilot operating characteristics – NA, no Pilot.
5.7 Automatic gas ignition systems – NA, not used
5.8 Direct ignition systems – NA, no direct ignition systems.
5.9 Manual ignition systems – Extended from report no.70030918
5.10 Manual operated gas valve – Waived, use certified type.
5.11 Gas appliance pressure regulators – NA, no gas appliance pressure regulators
5.12 Automatic valves – NA, no automatic valve.
5.13 Dual cylinder manifold – NA, use one cylinder only
5.14 Manifold and gas control assembly capacity – NA, no gas appliance pressure regulators