Instructions / Assembly

MASTER CONTRACT: 263865
REPORT: 70030918
PROJECT: 80056731
Page No: 44
Date Issued: September 30, 2020
DQD 507.10 Rev 2020-07-02 © 2020 CSA Group. All rights reserved.
The glass panels used on model GFT-97010 and GFT-93062 are to be removed.
The clearances to combustible ceiling and walls for all models are reduced to 64”.
GFT-80108, GFT-31202 and GFT-61358 are new models extended from model GFT-97010 except appearances
are different, which will not affect the test results.
Model GFT-60640 added in project 70207528 is changed as GFT-60640A.
According to above reasons, typical models GFT-60640 and GFT-97010 are chosen as typical models for below
tests and satisfactory result was found:
ANSI Z21.97-2017 / CSA 2.41-2017 Outdoor Decorative Gas Appliances
Section 1 Scope
Section 4 Construction -partial
Section 5 Performance
5.1 General
5.2 *Test Gases
5.3 *Test pressures and burner adjustments
5.4 *Combustion
5.5 *Burner operating characteristics
5.6 Pilot operating characteristics NA, no Pilot.
5.7 Automatic gas ignition systems NA, not used
5.8 Direct ignition systems NA, no direct ignition systems.
5.9 *Manual ignition systems
5.10 Manual operated gas valve Waived, use certified type.
5.11 Gas appliance pressure regulators NA, no gas appliance pressure regulators
5.12 Automatic valves NA, no automatic valve.
5.13 Dual cylinder manifold NA, use one cylinder only
5.14 Manifold and gas control assembly capacity NA, no gas appliance pressure regulators
5.15 Wall, floor and ceiling temperatures
5.16 *Rain test
5.17 *Wind test
5.18 Burner durability Extend from report no.70030918
5.19 Glass panels NA, no glass panels
5.20 Glass fronts NA, no glass panels
5.21 Appliance structure Extend from report no.70030918
5.22 Orifice and orifice fitting temperatures Extend from report no.70030918
5.23 Burn hazard potential NA, no glass panels
5.24 Marking material adhesion and legibility Waived, use certified type
Note: Tests with affix “*” also conducted with Natural Gas.
Test history of Project 70170918
The following tests were conducted in:
CCIC-CSA International Certification Co., Ltd.
No. 10, Ke Yan Road
Science Park