Material Safety Data Sheet
 UTILITY MANUFACTURING CO., INC. 
 700 MAIN STREET, WESTBURY, NY 11590 
 (516) 997-6300 - FAX # (516) 997-6345 
DO-ALL+PLUS FURNACE/REFRACTORY/RETORT CEMENT 
Page 2      30-1030 
MATERIAL SAFETY DATA SHEET 
SECTION VII - STORAGE AND SPECIAL PRECAUTIONS 
HANDLING AND STORAGE PRECAUTIONS: Do not get in eyes, skin or clothing. Do not breathe vapor mist or gas. Keep 
containers tightly closed, cool, dry, and away from all sources of ignition. Use and store this product with adequate ventilation. 
Avoid inhalation of vapors and personal contact with the product. Use good personal hygiene practices. Bond and ground 
equipment when transferring to another container. “Empty” containers contain residue (liquid and/or vapor) and can be 
dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks, or other 
sources of ignition.  They may explode and cause injury and death. Empty drums should be completely drained, properly 
bunged, and promptly shipped to the supplier or drum reconditioner. All other containers should be disposed of in an 
environmentally safe manner and in accordance with governmental regulations. Before working in or on tanks which contain or 
has contained his product, refer to OSHA or ANSI Z49.1 regulations and other governmental and industrial references 
pertaining to cleaning, repairing, welding, or other contemplated operations. 
SECTION VIII - FIRE AND EXPLOSION HAZARD DATA 
EXTINGUISHING MEDIA: Extinguish with dry chemical, CO
2
, or a universal type foam. 
FIRE AND EXPLOSION HAZARD: May decompose during contact with flames, heating elements, or in combustion engines releasing 
irritating gases. Container may explode if heated due to resulting pressure rise.       
FIRE FIGHTING PROCEDURES: Wear appropriate protective equipment including respiratory protection as conditions warrant (see 
Section IV). Stop spill/release if it can be done without risk. Water spray may be useful in minimizing or dispersing vapors and 
cooling equipment exposed to heat and flame. Avoid spreading burning liquid with water used for cooling purposes. 
SECTION IX - PHYSICAL DATA 
APPROXIMATE BOILING POINT (DEG F): NONE     PER CENT VOLATILE: NONE  
SPECIFIC GRAVITY (68 F):  >1        FLASH POINT (TCC, DEG F): NONE 
RELATIVE EVAPORATION RATE (ESTIMATED): <1    PER CENT SOLUBILITY IN WATER: <10 
VAPOR PRESSURE @20C mmHg (CALCULATED): <1 
SECTION X - OTHER REGULATORY DATA 
SARA               HMIS 
  SECTION 302: NONE          Health:    0   
  SECTION 311 & 312: NONE        Flammability:  0 
  SECTION 313: See Section I.I        Reactivity:  0 
TSCA 
  All components are in full compliance  CALIFORNIA PROPOSITION 65 
  with the TSCA inventory.      NOT LISTED 
RCRA            CERCLA 
  NOT REGULATED      NOT REGULATED 
CARCINOGENICITY: 
NOT LISTED with NTP or IARC. 
             NOTICE           
The supplier disclaims all expressed or implied warranties of merchantability or fitness for a specific use, with respect to the product or the information 
provided herein, except for conformation to contracted specifications. All information appearing herein is based upon data obtained from manufactures 
and/or recognized technical sources. While the information is believed to be accurate, we make no representations as to its accuracy or sufficiency. 
Conditions of use are beyond our control, and therefore users are responsible for verifying the data under their own operating conditions to determine 
whether the product is suitable for their particular purposes and they assume risks of their use, handling, and disposal of the product. Users also assume all 
risks in regards to the publication or use of, or reliance upon, information contained herein. This information relates only to the product designated herein, 
and does not relate to its use in combination with any other material or process. 