Instructions

4
TOOLS REQUIRED
PREPARATION
Hacksaw
Pipe wrenches (2)
Wire strippers
Needle-nose Pliers
Phillips screwdriver
Wire cutters
Adjustable wrench
PARTS REQUIRED FOR ASSEMBLY (not included)
(Fig. 1)
Item Qty Description
1 * 2 in. Sched 40 PVC pipe
2 * 1-1/2 in. Sched 40 PVC pipe
3 2 2 in. MPT x 2 in. slip adapter
4 1 1-1/2 in. MPT x 1-1/2 in. slip adapter
5 1 1-1/2 in. tee
6 1 1-1/2 in. slip x 1-1/4 in. FPT reducer
bushing
7 1 1-1/4 in. MPT plug
8 1 2 in. 90º elbow
9 1 1-1/2 in. 90º elbow
10 Teon tape
11 1 1/4 in. Romex strain relief
12 1 2-step PVC glue system (primer and
sealer
13 1 Teon paste
1
12
11
10
9
8
7
6
5
4
3
2
OPTIONAL PARTS FOR ASSEMBLY (not included)
(Fig 2)
1. Priming Plug with Pressure Gauge: Used instead
of a priming plug alone. Helps determine if the
pump is primed, indicates if the pump is operating
properly and what kind of pressure is in the
system when operating.
a. Qty. 1: 1-1/4 in. MPT x 1/2” FPT reducer
bushing.
b. Qty. 1: 1/2 in. MPT x 1/4 in. FPT reducer
bushing
c. Qty. 1: 100 PSI pressure gauge
2. Unions: Used for easy removal of the pump from
the sprinkler system.
a. Qty. 1: 2 in. union
b. Qty. 1: 1-1/2 in. union
3. 1-1/2 in. Ball Valve: Prevents back flow of water
from the sprinkler system when the pump is
removed from the system.
4. 1-1/2 in. Couplers: Quantity determined by the
total length of pipe used.
5. 2 in. Couplers: Quantity determined by the total
length of pipe used.
1c
5
4
3
2a
Fig 1
Fig 2
13
MPT Threads
FPT Threads
Fig 3
1b
1a
2b