STAR ® LAWN SPRINKLER, IRRIGATION PUMP MODEL #, HSP10P1, HSP15P1, HSP20P1 HSPJ07P1, HSPJ10P1, HSPJ15P1, HSPJ20B1 110 West Division St. | Boonville, IN 47601 www.starwatersystems.com Español p. 19 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m.-5:00 p.m., EST, Monday-Friday.
TABLE OF CONTENTS Safety Information.............................................................................................................................3 Preparation........................................................................................................................................3 General Pump Information................................................................................................................5 Pump Preparation for Well and Surface Water...................
SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. If you have any questions regarding the product, please call customer service at 1-800-742-5044, 7:30 a.m.-5:00 p.m., EST, Monday-Friday. 1. 2. 3. 4. 5. WARNING: Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). WARNING: Replace damaged or worn wiring cord immediately.
PREPARATION TOOLS REQUIRED Hacksaw Pipe wrenches (2) Phillips screwdriver Wire strippers Adjustable wrench Needle-nose Pliers Fig 1 7 Wire cutters 6 Qty * * 2 1 1 1 7 8 9 10 11 12 1 1 1 13 1 1 1 Description 2 in. Sched 40 PVC pipe 1-1/2 in. Sched 40 PVC pipe 2 in. MPT x 2 in. slip adapter 1-1/2 in. MPT x 1-1/2 in. slip adapter 1-1/2 in. tee 1-1/2 in. slip x 1-1/4 in. FPT reducer bushing 1-1/4 in. MPT plug 2 in. 90º elbow 1-1/2 in. 90º elbow Teflon tape 1/4 in.
GENERAL PUMP INFORMATION TYPICAL PUMP SETUP Typical setups for lawn sprinkler pump systems include ground water wells (Fig. 4) or surface water, such as lakes, ponds or streams. (Fig. 5) Fig 4 Horizontal Distance Discharge Pipe Pipe Support LOCATION For best performance, the pump should be located as close to the water source as possible. Suction Lift VENTILATION Ventilation and drainage must be provided to prevent damage to the motor from heat and moisture. 25 ft.
PUMP PREPARATION FOR WELL AND SURFACE WATER CAUTION: Dry-fit entire assembly (pages 7-9) to ensure proper fit before gluing or taping parts. Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 CAUTION: Follow all proper gluing procedures as specified by the glue manufacturer. Always glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings CAUTION: Use Teflon tape and a Teflon paste compound on all male threads except for the unions.
PUMP PREPARATION FOR WELL AND SURFACE WATER FOR WELL INSTALLATIONS 1. Thread the 2 in. MPT x 2 in. slip adapter into the 2 in. foot valve which is included with the pump. (Fig. 17) 2. Glue 2 in. pipe into the adapter. Glue enough sections of pipe together using 2 in. couplers in order for the foot valve to be completely submerged in water. Be sure suction pipe will remain fully submerged at the lowest expected level of the water source. (Fig. 18 & 19) 3.
PUMP INSTALLATION FOR WELL AND SURFACE WATER 1. Mount pump on a solid foundation as close to the water source as possible. (Fig. 24) 2. Glue enough sections of pipe to connect the 2 in. suction line from the well or lake (done in the well preparation section) to reach the 2 in. suction male union (done in the pump preparation section.
PUMP ELECTRICAL INSTRUCTIONS Fig 27 CAUTION: All wiring should be performed by a qualified electrician in accordance with the National Electric Code and local electric codes. Distance From Motor To Fuse Box, Meter or Electrical Outlet CAUTION: Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Reference Fig. 27 for proper fuse size. WARNING: Under-size wiring can cause motor failure and even fire. Use proper wire size specified in the Wire size chart. (Fig. 27) 0-50 Ft.
PUMP ELECTRICAL CONNECTIONS 230V TO 115V MOTOR VOLTAGE CHANGE 1. This pump motor is dual voltage and can run on either 115V or 230V. In general, 230V is more economical to run, and requires a smaller wire size. Fig 34 Fig 35 Fig 36 Fig 37 Fig 38 Fig 39 2. This pump motor is wired from the factory to run on 230V. (Fig. 34) 3. For 115V service,change the following wires on the terminal board: a.
PUMP PRIMING & STARTUP Fig 40 CAUTION: All pumps must be primed (filling the pump cavity with water) before they are first operated. This may take several gallons of water, as the entire suction line will be filled in addition to the pump cavity. The longer the suction line, the more water is required to prime. 1. D isconnect the 1-1/2 in. discharge union and separate the pipe. (Fig. 40) Priming plug with pressure gauge Discharge Air relief plug Suction line 2.
PUMP PRIMING & STARTUP (CONTINUED) 4. R eplace air relief plug and continue adding water to pump cavity until water comes out of the open discharge pipe at the open union. (Fig. 43) Fig 43 5. Thread in the priming plug. (Fig. 44) Fig 44 6. R econnect 1-1/2 in. union on discharge pipe. Open the ball valve (turn handle to line up with pipe), and then turn on breaker to start pump. (Fig.
PUMP PRIMING & STARTUP (CONTINUED) Fig 46 IMPORTANT: If the pump hums instead of pumping or turns off repeatedly, shut pump off immediately. Check voltage. Pump is wired to run on 230V. If the pump cuts out or stops, you may be attempting to connect to 115V. See Motor Voltage Change instructions to change motor voltage to 115V. Pipe Support Check pipe for sagging IMPORTANT: If the pump fails to prime within five minutes: 1. Turn power off at the breaker box. 2. Check all pipe connections for leaks.
SPECIFICATIONS MOTOR DATA CHART - HSPJ SERIES MOTOR DATA CHART - HSP SERIES Code Letter Max Amps Locked Rotor Amps Code Letter Max Amps Locked Rotor Amps HP Phase Volts 62.0 31.0 3/4 1 115 230 K 14.0 52.0 18.00 9.00 72.0 36.0 1 1 115 230 l 18.0 70.0 21.00 10.50 108.0 54.0 1-1/2 1 115 230 J 21.0 98.0 2 1 115 230 H 25.0 116.0 HP Phase Volts 1 1 1 115 230 H 17.6 8.
TROUBLESHOOTING Problem Little or no discharge Possible Cause Corrective Action 1. Casing not initially filled with water 2. Suction lift too high, or too long 3. Hole or air leak in suction line 4. Foot valve too small Pump will not deliver water or develop pressure Loss of suction Pump vibrates and/or makes excessive noise Pump will not start or run 5. F oot valve or suction line not submerged deep enough in water 6. Motor wired incorrectly 7. Casing gasket leaking 8.
REPLACEMENT PARTS LIST To order parts, call 1-800-742-5044 1 HSP SERIES A B C E D F G 2 4 HSPJ SERIES 7 H 3 Motor Assembly 5 11 6 9 8 12 HSP SERIES 13 10 IL0174 HP 1 1-1/2 2 SINGLE PHASE MODEL NO. HSP10P1 HSP15P1 HSP20P1 A B C D E F DESCRIPTION Ring, Square Cut Seal, Rotary and Ceramic (with Spring) Impeller Diffuser Diffuser Insert Rubber Diffuser PART NO.
SW0736 1110 Supersedes NEW THIS PLAN COVERS: LIGHTNING DEFECTS IN MATERIAL CORROSION DEFECTS IN WORKMANSHIP ABRASION WITH THE PURCHASE OF THIS PLAN, your Star jet pump, submersible pump, or HSPJ centrifugal pump will be replaced or repaired at no charge to you if the pump fails within five years from date or original purchase or six years from date of manufacture, whichever occurs first, if failure occurs due to damage from lightning, abrasion, corrosion, or due to defects in material or wor
5 YEAR PUMP PROTECTION PLAN AGREEMENT FORM Must be submitted along with sales receipt within 30 days of pump purchase date. STAR ® This agreement is valid once accepted by Star Water Systems, and returned to the consumer. For replacement or repair only. Not valid on cash refund. INSTRUCTIONS: To apply for 5 Year Pump Protection, complete the following steps: 1. Read program details carefully 2. Mail completed agreement along with pump sales receipt and check or money order for $30.
STAR ® 110 West Division St. | Boonville, IN 47601 www.starwatersystems.com REGADOR DE CÉSPED, BOMBA DE IRRIGACIÓN ARTÍCULO #, HSP10P1, HSP15P1, HSP20P1 HSPJ07P1, HSPJ10P1, HSPJ15P1, HSPJ20B1 ¿Preguntas, problemas, piezas faltantes? Antes de volver a la tienda, comuníquese con nuestro Departamento de Servicio al Cliente al 1-800-742-5044, de lunes a viernes, de 07:30 a.m. a 5:00 p.m. (hora estándar del Este) o envíe un correo electrónico a: tech@starwatersystems.com.
ÍNDICE Información de seguridad................................................................................................................................................. 3 Preparación...................................................................................................................................................................3-4 Información general acerca de la bomba.....................................................................................................................
INFORMACIÓN DE SEGURIDAD Lea y comprenda completamente este manual antes de intentar ensamblar, usar o instalar el producto. Si tiene alguna pregunta sobre el producto, comuníquese con el Departamento de Servicio al Cliente al 1-800-742-5044, de lunes a viernes, de 07:30 a.m. a 5:00 p.m. (hora estándar del Este). 1. 2. 3. 4. 5. 6.
PREPARACIÓN OUTILS REQUIS Sierra de mano 2 llaves para tuberías Pinzas cortacables Pinzas de punta fina Fig 1 Destornillador Phillips Pinzas pelacables Llave ajustable 7 6 PIEZAS NECESARIAS PARA EL ENSAMBLAJE (NO SE INCLUYEN) (FIG. 1) Artículo 1 2 3 4 5 6 7 8 9 10 11 12 13 Cant.
INFORMACIÓN GENERAL ACERCA DE LA BOMBA CONFIGURACIÓN TÍPICA DE LA BOMBA Las configuraciones típicas para los sistemas de bomba de riego para césped incluyen pozos de agua del subsuelo (Fig. 4) o agua superficial, como lagos, estanques o arroyos. (Fig. 5) Fig 4 Distancia Horizontal UBICACIÓN La bomba se debe colocar lo más cerca posible de la fuente de agua para obtener un mejor rendimiento.
PREPARACIÓN DE LA BOMBA PARA POZO Y AGUA SUPERFICIAL PRECAUCIÓN: Ajuste completamente el ensamble (páginas 6-8) para asegurarse de obtener un ajuste adecuado antes de unir las piezas definitivamente. Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 PRECAUCIÓN: Siga todos los procedimientos adecuados para unir como lo especifica el fabricante de adhesivo.
PREPARACIÓN DE LA BOMBA PARA POZO Y AGUA SUPERFICIAL PARA POZOS 1. Enrosque el MPT de 2” x 2” de la válvula de pie que se incluye con la bomba. (Fig. 17) 2. Una con adhesivo la tubería de 2” dentro del adaptador. Una con adhesivo y con acopladores de 2” suficientes secciones de la tubería para que la válvula de pie esté completamente sumergida en el agua. Asegúrese de que la tubería de succión permanezca totalmente sumergida en el nivel más bajo posible de la fuente de agua. (Fig. 18 y 19) 3.
ENSAMBLAJE DE LA BOMBA PARA AGUA DE POZO Y SUPERFICIE 1. Monte la bomba en un cimiento sólido tan cerca como sea posible de la fuente de agua. (Fig. 24) 2. Una con adhesivo suficientes secciones de la tubería para conectar la línea de succión de 2” del pozo o lago (hecho en la sección de preparación del pozo) para alcanzar la unión de succión macho de 2” (hecha en la sección de preparación de la bomba). 3. 4. 5. 6. 7. 8. 9.
BOMBEO DE LAS CONEXIONES ELÉCTRICAS PRECAUCIÓN: Todo el cableado debe ser realizado por un electricista calificado de acuerdo con el Código nacional de electricidad y los códigos locales de electricidad. Fig 27 TABLA DE TAMAÑOS DEL CABLE Distancia desde el motor hasta la caja de fusibles, medidor o tomacorrientes PRECAUCIÓN: Conecte la bomba a un circuito eléctrico separado con un interruptor de circuito dedicado. Referencia Fig. 27 para obtener el tamaño adecuado de fusible.
BOMBEO DE LAS CONEXIONES ELÉCTRICAS Cambio De Voltaje Del Motor De 230 A 115 Voltios 1. El motor de esta bomba es de voltaje doble y puede funcionar con 115 ó 230 voltios. En general, es más económico cuando funciona con 230 voltios y necesita cable de menor tamaño. 2. El motor de esta bomba tiene un cableado de fábrica que le permite funcionar con 230 voltios. (Fig. 34) 3. Para que funcione con 115 voltios, cambie los siguientes cables en el tablero de terminales. 4.
CEBADO Y ARRANQUE DE LA BOMBA Cebado PRECAUCIÓN: Todas las bombas deben cebarse (llenar la cavidad con agua) antes de hacerlas funcionar por primera vez. Esto puede requerir de varios galones de agua, porque la se llenará la línea de succión y la cavidad de la bomba. 1. Desconecta la unión de descarga de 1-1/2” y separe la tubería. (Fig. 40) 2. Retire el tapón de cebado de 1-1/4 pulgadas con indicador de presión. (Fig. 41) 3.
PREPARACIÓN PARA EL INVIERNO CONGELAMIENTO Fig 46 PRECAUCIÓN: Drene todo el sistema si existe peligro de congelamiento. En el fondo de la caja de la bomba, encontrará un tapón de drenaje para este propósito. (Fig. 46). EVITE DAÑOS EN LA BOMBA Retire el tapón cuando el clima esté muy frío ESPECIFICACIONES TABLA DE DATOS DEL MOTOR - HSP SERIE Letra Amperaje Amperaje del Fase Voltios código máximo rotor bloqueado HP 1 1 1 115 230 H 17.6 8.8 62.0 31.0 1-1/2 1 1 115 230 G 18.0 9.0 72.0 36.
ESPECIFICACIONES RENDIMIENTO - HSP SERIE Artículo 0313831 0313833 0313834 Capacidad: Galones americanos por presión de descarga por hora (PSI) Elevación de succión (pies) HP 1 1-1/2 2 Artículo HP HSPJ07P1 3/4 HSPJ10P1 1 HSPJ15P1 1-1/2 HSPJ20B1 2 HSPJ30B1 3 15 20 25 30 35 40 10 3420 3120 2700 2100 1200 0 15 2820 2640 2220 1800 600 0 20 2640 2520 2160 1500 480 0 25 1440 1380 1320 1020 300 0 10 3960 3480 3180 2520 1920 600 15 3720 3420 2820 228
LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS Problema Mínima o nula descarga La bomba no proporciona agua ni genera presión Pérdida de succión Causa posible Acción correctiva 1. E l entubado no está inicialmente relleno con agua 1. L lene el entubado de la bomba 2. L a altura total está demasiado elevada 2. A corte la elevación de succión y/o cambie la altura 3. L a elevación de succión está demasiado alta o demasiado larga 3.
LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS Problema La bomba vibra y/o hace demasiado ruido La bomba no enciende ni funciona La bomba tiene una fuga en el eje Causa posible Acción correctiva 1. La placa de montaje o base no están lo suficientemente rígidas 1. R efuerce 2. Hay material extraño en la bomba 2. D esensamble la bomba y límpiela 3. El impulsor está dañado 3. R eemplace 4. Los cojinetes del motor están gastados 4. R eemplace 5.
LISTA DE PIEZAS DE REPUESTO Para obtener piezas de repuesto, llame a nuestro Departamento de Servicio al Cliente al 1-800-742-5044 de 7:30 a.m. a 5:00 p.m., hora estándar del Este. 1 HSP Serie A B C E D F G 2 4 HSPJ Serie 7 H 3 Ensamble del motor 5 11 6 9 8 12 HSP Serie ARTÍCULO 13 HP 1 MONOFÁSICOS MODELO NO. UTP10P1 DESCRIPCIÓN PIEZA NO.