Installation Guide
16
Lowes.com
MOTOR DATA CHART
HP Phase Volts Code Letter Max Amps
Locked Rotor
Amps
1/3 1 115 A 3.1 9.5
PERFORMANCE
Item
Number
HP Ft. of Head Flow (GPM)
Shut Off
Head (Ft.)
Discharge
Size
0240055 1/3
538
18 1-1/2 in.10 30
15 14
SPECIFICATIONS
Problem Possible Cause Corrective Action
Capacity or flow
drops after a
period of use.
1. Clogged inlet or discharge pipe. 1. Clean all piping.
2. Check valve clogged or defective. 2. Be sure check valve is installed and
operating properly. Replace check
valve if necessary.
3. Abrasive material or chemicals
damaged impeller or pump housing.
3. Remove base and inspect.
TROUBLESHOOTING