Operating Guide
2
 WARNING
Improper installation, adjustment, alteration, service or 
maintenance can cause death, serious bodily injury or property 
damage. Refer to this manual for further assistance.
 WARNING
This water tank is designed and intended for cold (ambient 
temperature) water storage at a maximum pressure of 125 PSIG,  
any use other than with cold water, or at a sustained or 
instantaneous pressure in excess of 125 PSIG is unsafe. A 
pressure relief valve of adequate size must be incorporated in the 
system. The relief valve must be selected to pass the full capacity 
of the pump when the pressure in this tank is 125 PSIG or less. 
Consult pump manufacturer for pump capacity at relief pressure. 
The manufacturer of this tank does not accept any liability or other 
responsibility for personal injury or property damage resulting  
from improper use, installation, or operation of this tank, or of the 
system of which it is a part.
 DANGER
Failure to follow these instructions can cause tank to blow-up 
and result in death, serious bodily injury or property damage.
Install a 125 PSI or less pressure relief valve directly into a 
tubing so that any discharge will exit only within 6 inches above, 
contact is made with any live electrical part. The discharge 
opening must not be blocked or reduced in size under any 
circumstances. Excessive length, over 30 feet, or use of more 
than four elbows can cause restriction and reduce the discharge 
capacity of the valve.
No valve or other obstruction is to be placed between the relief 
valve and the tank. Do not connect tubing directly to discharge 
drain unless a 6” air gap is provided. To prevent bodily injury, 
hazard to life, or property damage, the relief valve must be allowed 
to discharge water in quantities should circumstances demand. 
If the discharge pipe is not connected to a drain or other suitable 
The Discharge Pipe: 
 
or have any reducing couplings or other restriction.
 
 
pressure relief valve, and the discharge pipe.
 
 WARNING
Review the Installation Check List before turning on electric 
power to safeguard against possible dangerous malfunction of 
the pump tank.
 WARNING
The complete pump, tank, pressure relief valve, pressure switch 
and piping system MUST be protected against below freezing 
temperature. Failure to do so could cause tank to blow-up and 
result in death, serious bodily injury or property damage.
SAFETY PRECAUTIONS
TABLE OF CONTENTS .................................................................................................................................................................................................. 2
SAFETY PRECAUTIONS ............................................................................................................................................................................................... 2
SAFE INSTALLATION USE AND SERVICE................................................................................................................................................................... 3
PREPARING FOR NEW INSTALLATION ....................................................................................................................................................................... 4
MATERIALS AND BASIC TOOLS NEEDED .................................................................................................................................................................. 4
 Materials ..................................................................................................................................................................................................................... 4
 Basic Tools ................................................................................................................................................................................................................. 4
REMOVING THE OLD PUMP TANK .............................................................................................................................................................................. 4
LOCATING THE NEW PUMP TANK .............................................................................................................................................................................. 5
  Facts to Consider About the Location ........................................................................................................................................................................ 5
INSTALLING THE NEW PUMP TANK ........................................................................................................................................................................ 5–7
 Water Piping ............................................................................................................................................................................................................... 5
    Jet Pump (Shallow or Deep Well ) Typical Installation ........................................................................................................................................... 5
 Submersible Pump Typical Installation ................................................................................................................................................................... 6
    Optional Installation (Shallow or Deep Well ) ......................................................................................................................................................... 6
  Pressure Relief Valve ................................................................................................................................................................................................. 7
  Filling the Pump Tank ................................................................................................................................................................................................. 7
 Installation Checklist ................................................................................................................................................................................................... 7
FOR YOUR INFORMATION ....................................................................................................................................................................................... 7–8
 Operational Conditions ............................................................................................................................................................................................... 7
 How Pump Tanks Operate...................................................................................................................................................................................... 7
 Water Logged Condition ......................................................................................................................................................................................... 8
PERIODIC MAINTENANCE ........................................................................................................................................................................................... 9 
Pressure Relief Valve Operation .................................................................................................................................................................................... 9 
Service............................................................................................................................................................................................................................ 9
Anode Rod Inspection .................................................................................................................................................................................................... 9
WARRANTY ............................................................................................................................................................................................................10–11
TABLE OF CONTENTS