Installation Guide
9
EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS
3.    Remove the three screws (3.1) that hold the motor  
assembly (3.2) in place. Remove the fan motor 
assembly (3.2) from the fan housing (A). Unplug the 
fan power unit (3.3). 
4.   Remove the wiring box cover (4.1) from the fan 
housing (A). Remove the wiring knockout (4.2) from 
the wiring box cover (4.1) with a athead screwdriver 
(not included).
5.   Pull the house wires through the wire box cover hole. 
Using a quick connector, secure 120 V AC house wiring 
from the wall switch to the fan as shown in the wiring 
diagram on page 5. 14 AWG is the smallest conductor 
that should be used for branch-circuit wiring. 
   Carefully push the connected wires back into the wiring 
box housing. Reattach the wiring box cover.
 CAUTION: If the electrical wires do not match the 
colors listed, you must determine what each house wire 
represents before connecting. You may need to consult 
an electrical contractor to determine safely.
4
4
3.1
3.2
A
4.1
4.2
A
3.3
5