ITEM #0955549 CAST IRON JET PUMP MODEL #148012 Español p. 21 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date SW1190 C Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-994-4148, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
PRODUCT SPECIFICATIONS Power supply required............................................................................115 volts or 230 volts, 60 Hz (Pump is set by the factory to run on 115 volts) Maximum water temperature............................................................................................77°F (25°C) Individual branch circuit required............................................................................. 15 Amp minimum Discharge connection.....................................
• • • • • • • • ELECTRICAL SHOCK ALERT. Wire motor to correct supply voltage. See motor nameplate and wiring diagrams and check voltage of power supply. ELECTRICAL SHOCK ALERT. Unit must be securely and adequately electrically grounded. This can be accomplished by wiring the unit to a ground metal-clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means. ELECTRICAL SHOCK ALERT. Do not disassemble the motor housing.
PACKAGE CONTENTS Part A Description Pump CAUTION Quantity 1 A PREPARATION Before beginning installation of product, make sure all parts are present. If any part is missing or damaged, do not attempt to assemble the product. Compare parts to package contents list. Estimated Installation Time: 2 hours.
2. J et pumps can also be used with dug wells, driven wells, or with cisterns or lakes. 2 1 in. Discharge Pipe Discharge to Home A Suction Lift 25 ft. Max. 1-1/4 in. Suction Pipe Water Level Drive Point Ventilation - Ventilation and drainage must be provided to prevent damage to the motor from heat and moisture. Freezing - Pump (A) and all piping must be protected from freezing. If freezing weather is forecast, drain pump or remove completely from the system.
WELL TO PUMP CONNECTION (SUCTION PIPE) CAUTION: Dry-fit entire assembly to ensure proper fit before gluing or taping parts. CAUTION: Follow all proper gluing procedures as specified by the glue manufacturer. Always glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings CAUTION: Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to a snug fit and add another 1/4 turn to ensure proper seal. 1. Thread 1-1/4 in.
3. Before sliding the pipe assembly into the well, firmly clamp the assembly with a pipe clamp (not included) to prevent the assembly from sliding down into the well. 3 25 ft. maximum Pipe clamp Water level 5 ft. minimum 4. Remove the pipe clamp and slide a well seal (not included) over the PVC pipe and onto the well casing. The PVC pipe should extend approximately 12 in. above the top of the well seal, depending on the height of the pump. 4 Approx. 12 in.
6. Wrap thread tape (not included) around the threads of a 1-1/4 in. male PVC adapter (not included). Thread the adapter into the 1-1/4 in. opening in the front of pump (A). 6 1-1/4 in. Male PVC adapter 7. An optional 1-1/4 in. union (not included) is recommended for easy connection and disconnection. A 7 A 1-1/4 in. Union 8. Using 2-step PVC system, attach 1-1/4 in. PVC pipe and couplings as needed to connect the 1-1/4 in. male PVC adapter to the 1-1/4 in.
CHECK TANK PRESSURE 1. Completely drain all water from tank by turning off pump and opening a faucet until water stops. 20 20 20 20 1 Breaker Box 2. Use a pressure gauge to ensure it’s set to 18 PSI. 2 a. Use a tire pump to adjust the PSI to 18 PSI Pressure gauge b. If water leaks from the air release valve, replace the pressure tank. Set to 18 psi Air release valve PUMP TO TANK CONNECTION (DISCHARGE PIPE) 1. Wrap thread tape around threads of a 1 in. discharge tee (not included).
2. Install a 1 in. MPT x 1/4 in. FPT galvanized bushing and (optional) pressure gauge (both not included), or a pipe plug (not included). Do not tighten, as you will prime pump (A) later at this location. 2 Pressure Gauge or Pipe Plug with Bushing A 3. Wrap thread tape around the threads of a 1 in. male PVC adapter (not included) and thread the adapter into the discharge tee. 3 1 in. male PVC adapter A 4. Continue with 1 in. fittings and pipe to the pressure tank. An optional 1 in.
TANK TO HOUSE CONNECTION 1. Most pressure tanks will have a 1 in. inlet elbow on the bottom. Connect to this elbow with a 1 in. MPT x 1 in. slip (glue) adapter and short piece of pipe. 1 Adapter IL1365 Glue Pipe 2. Attach a 1 in. elbow (not included) to the pipe. 2 Elbow IL1366 Glue 3. Attach a 1 in. pipe (not included) to the elbow and a 1 in. x 3/4 in. reducer bushing (not included) to the pipe. 3 1 in.
4. A ttach a 3/4 in. pipe (not included) to the reducer bushing. Install an optional 3/4 in. union (not included) and continue with pipe and 3/4 in. x 3/4 in. x 3/4 in. tee (not included). 4 Tee Glue Union 1 in. pipe 5. A ttach the pipe from the pump to the tee installed in Step 4. Then, from the tee, install 3/4 in. pipe and optional shut off valve (not included) to connect tee to house plumbing. 5 Glue From Pump Shut off valve To House Plumbing Reducer Bushing IL1369 6.
PUMP ELECTRICAL CONNECTIONS • • • • • • • • WARNING: Always disconnect pump from electricity before performing any work on the motor. Under-sized wiring can cause motor failure and even fire. Use proper wire size specified in the Wire Size Chart. Replace damaged or worn wiring cord immediately. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals. The pump must be properly grounded using the proper wire cable with ground.
2. To connect the pressure switch, remove the switch cover and insert an electrical wire strain relief (not included) into the opening in the side of the pressure switch. 2 Wire from motor Strain relief Pressure switch IL1376 3. Thread the electrical wire (not included) from the power supply through the strain relief and tighten both screws on the strain relief. Do not crush wire. 3 4. Connect the two wires from the power supply to the two outside terminals on the pressure switch.
5. Connect the green ground wire from the power supply to the remaining green ground screw in the pressure switch and re-attach the pressure switch cover. 5 Ground Screws Wire from motor Wire from power supply Green ground wire PUMP PRIMING AND STARTUP PRIMING 1 CAUTION: All pumps must be primed (filling the cavity with water) before they are first operated. This may take several gallons of water, as the suction pipe will be filled in addition to the cavity of pump (A). 1.
PUMP PRIMING AND STARTUP 3. B e sure entire suction pipe is filled when priming. Depending on the length of suction pipe, many gallons will be needed to fill the entire system. 3 A Suction pipe 4. Check to be sure water in the cavity of pump (A) stays constant. If water level goes down, it could indicate a leak in the foot valve, check valve or suction pipe. 4 Water Level Suction pipe Check for leaks 5.
20 6 IMPORTANT: If the pump hums instead of pumping or turns off repeatedly, shut pump off immediately. Check voltage. Make sure your incoming voltage matches the pump wiring voltage. See PUMP ELECTRICAL CONNECTIONS. 20 6. Turn on breaker to start pump. 7. Check suction pipe for any sagging. Support suction pipe in a straight line to the pump (A). 20 IMPORTANT: If pump (A) fails to prime within five minutes: Turn power off at the breaker box and check all pipe connections for leaks.
TROUBLESHOOTING PROBLEM Little or no discharge POSSIBLE CAUSE 1. P ump is not primed 2. Suction lift too high or too long 3. Hole or air leak in suction line 4. Foot valve too small 5. F oot valve or suction line not submerged deep enough in water 6. Voltage switch incorrect Pump will not deliver water or develop pressure Pump vibrates and/or makes excessive noise Pump will not start or run 7. Casing gasket leaking 1. P ump is not primed 2. L eak in suction line 3.
WARRANTY This product is warranted for one year from the date of purchase or two years from the date of manufacture, whichever occurs first. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves defective due to defective materials or workmanship. This warranty does not cover replacement parts for failure due to normal wear and tear.
REPLACEMENT PARTS LIST There are no warranty replacement parts available for this product. For non-warranty replacement parts listed below, call our customer service department at 1-866-994-4148, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday. PART B C D DESCRIPTION O-rings / Nozzle / Venturi Kit Repair Kit (Includes Diffuser, Impeller Seal and O-Ring Pressure Switch PART NO.
ARTÍCULO #0955549 BOMBA DE CHORRO DE POZO DE POCA PROFUNDIDAD MODELO #148012 ADJUNTE SU RECIBO AQUÍ Fecha de compra ¿Preguntas, problemas, piezas faltantes? Antes de volver a la tienda, comuníquese con nuestro Departamento de Servicio al Cliente al 1-866-994-4148, 7:30 a.m. a 5:00 p.m., hora estándar del Este.
ESPECIFICACIONES DEL PRODUCTO Suministro de electricidad necesario................................................. 115 voltios o 230 voltios, 60 Hz (La bomba está configurada de fábrica para funcionar a 115 voltios) Temperatura máxima del agua.........................................................................................25°C (77°F) Circuito de derivación individual necesario........................................................ 15 amperios mínimo Conexión de descarga............................
• • • • • • • • ALERTA DE DESCARGA ELÉCTRICA. Conecte el motor al voltaje de alimentación correcto: Consulte la placa de datos y los diagramas de cableado del motor y revise el voltaje del suministro de electricidad. ALERTA DE DESCARGA ELÉCTRICA. La unidad debe contar con una puesta eléctrica a tierra segura y apropiada.
CONTENIDO DEL PAQUETE PIEZA A DESCRIPCIÓN Bomba CAUTION CANTIDAD 1 A PREPARACIÓN Antes de comenzar a instalar el producto, asegúrese de tener todas las piezas. No intente ensamblar el producto si falta alguna pieza o si estas están dañadas. Compare las piezas con la lista del contenido del paquete. Tiempo estimado de instalación: 2 horas.
2. Las bombas de chorro también pueden usarse en pozos excavados, pozos de hinca o con cisternas o lagos. 2 Tubo de descarga de 1 pulg. Descarga a la casa A Elevación de succión 7,62 m máx. Tubo de succión de 1-1/4 pulg. Nivel de agua Adaptador macho de 1-1/4 pulg. x 1 pulg. Válvula de pie de 1-1/4 pulg. Ventilación: se debe proporcionar ventilación y drenaje para evitar daños al motor producto de la humedad y el calor.
CONEXIÓN DESDE EL POZO HACIA LA BOMBA (TUBERÍA DE SUCCIÓN) PRECAUCIÓN: ajuste completamente el ensamble para asegurarse de obtener un ajuste adecuado antes de unir las piezas definitivamente. PRECAUCIÓN: siga todos los procedimientos adecuados para unir como lo especifica el fabricante de adhesivo. Siempre que sea posible coloque el adhesivo en dirección vertical para evitar que gotee dentro de la tubería o los conectores.
3. Antes de deslizar el ensamble del tubo en el pozo, fije con firmeza el ensamble con una abrazadera para tubería (no se incluye) para evitar que el ensamble caiga al pozo. 3 7,62 m como máximo Abrazadera para tubería Nivel de agua 1,52 m como mínimo 4. R etire la abrazadera para tubería y deslice el sello para pozo (no se incluye) sobre el tubo de PVC y el entubado del pozo.
6. A plique cinta para roscas (no se incluye) alrededor de las roscas de un adaptador macho de PVC de 1-1/4 pulg. (no se incluye). Enrosque el adaptador en la abertura de 1-1/4 pulg en la parte frontal de la bomba/tanque (A). 6 A Adaptador macho de PVC de 1-1/4 pulg. 7. S e recomienda usar una unión de 1-1/4 pulg. (no se incluye) para facilitar la conexión y la desconexión. 7 Unión de 1-1/4 pulg. 8. Usando un sistema de PVC de 2 pasos, fije una tubo de PVC y acopladores de 1-1/4 pulg.
REVISE LA PRESIÓN DEL TANQUE 1. Drene toda el agua del tanque apagando la bomba y abriendo un grifo hasta que el agua se detenga. 20 20 20 20 1 caja de disyuntores 2. Use un indicador de presión para asegurarse de que esté en 18 psi. 2 a. Use una bomba para neumáticos para ajustar los psi en 18 psi. Indicador Válvula de de presión descarga de aire Establezca en 18 psi b. Si el agua se filtra por la válvula de descarga de aire, reemplace el tanque de presión.
2. Instale un conector galvanizado de 1 pulg. MPT x 1/4 pulg. FPT y un indicador de presión (opcional) (no se incluyen) o un tapón para tubería (no se incluye). No apriete ahora, ya que después tendrá que cebar la bomba (A) en este lugar. 2 Indicador de presión o tapón para tuberías con conector A 3. E nrolle cinta para roscas alrededor de las roscas de un adaptador macho de PVC de 1 pulg (no se incluye) y enrosque el adaptador en el conector de descarga. 3 Adaptador macho de PVC de 1 pulg. A 4.
CONEXIÓN DESDE EL TANQUE A LA CASA 1. L a mayoría de los tanques de presión cuentan con un codo de entrada de 1 pulg. en la parte inferior. Conecte este codo con un adaptador deslizante (adhesivo) de 1 pulg MPT x 1 pulg. y la pieza corta del tubo. 1 Adaptador IL1365 2. F ije un codo de 1 pulg. (no se incluye) al tubo. Adhesivo Tubo 2 Codo IL1366 Adhesivo 3. Fije un tubo de 1 pulg. (no se incluye) al codo y una boquilla reductora de 1 pulg. x 3/4 de pulg. (no se incluye) al tubo.
4. Conecte el tubo de 3/4 de pulg. (no se incluyen) a la boquilla reductora. Instale una unión opcional de 3/4 de pulg. (no se incluye) y continúe con el tubo y una T de 3/4 de pulg. x 3/4 de pulg. (no se incluye). 4 T Adhesivo Unión Tubo de 1 de pulg. Boquilla reductora 5. Instale el tubo de la bomba al conector instalado en el Paso 4. Luego, desde el conector, instale un tubo de 3/4 pulg. y una válvula de cierre opcional (no se incluye) para conectar el conector en T a la plomería de la casa.
CONEXIONES ELÉCTRICAS DE LA BOMBA. • • • • • • • • ADVERTENCIA: Siempre desconecte la bomba de la fuente de energía antes de llevar a cabo cualquier trabajo en el motor. Un cableado de tamaño menor puede causar fallas en el motor e incluso incendios. Use el tamaño adecuado de cable especificado en la tabla correspondiente. Reemplace inmediatamente los cables dañados o desgastados.
2. Para conectar el interruptor de presión, retire la cubierta del interruptor e inserte un aliviador de tensión para cable eléctrico (no se incluye) en la apertura al costado del interruptor de presión. 2 Cable desde el motor Aliviador de tensión Interruptor de presión IL1376 3. Pase el cable eléctrico (no se incluye) del suministro de electricidad a través del aliviador de tensión y apriete ambos tornillos en el aliviador de tensión. No aplaste el cable.
5. Conecte el conductor de puesta a tierra verde del suministro de electricidad al tornillo de puesta a tierra verde que queda en el interruptor de presión y vuelva a colocar la cubierta del interruptor de presión. 5 Tornillos de puesta a tierra Cable desde el motor Cable desde el suministro de electricidad Alambre de tierra eléctrica verde CEBADO Y ARRANQUE DE LA BOMBA CEBADO 1 PRECAUCIÓN: todas las bombas deben cebarse (llenado de la cavidad con agua) antes de hacerlas funcionar por primera vez.
3. A segúrese de que la tubería de succión se llene completamente al realizar el cebado. Dependiendo de la longitud de la tubería de succión, podrían necesitarse varios litros para llenar completamente el sistema. 3 A Tubería de succión 4. Asegúrese de que el nivel de agua en la cavidad de la bomba (A) sea constante. Si el nivel del agua baja, podría haber una fuga en la válvula de pie. Revise la válvula o el tubo de succión. 4 Nivel de agua Tubería de succión 5.
6. Encienda el interruptor para arrancar la bomba. 7 Tubería de succión de 1-1/4 pulg. Pozo Válvula de pie CUIDADO Y MANTENIMIENTO 1 PRECAUCIÓN: drene todo el sistema si existe peligro de congelamiento. 1. Para drenar la bomba (A), retire el tapón de drenaje ubicado en la parte frontal de la bomba (A) y el tapón de ventilación ubicado en la parte superior. Tapón de ventilación Tapón de drenaje 37 20 Tubería de descarga de 1 pulg.
SOLUCIÓN DE PROBLEMAS PROBLEMA Descarga mínima o nula CAUSA POSIBLE ACCIÓN CORRECTIVA 1. La bomba no está cebada 2. La elevación de succión es demasiado alta o demasiado larga 3. Hay un orificio o una fuga de aire en el tubo de succión 4. La válvula de pie es demasiado pequeña 5. La válvula de pie o el tubo de succión no están bien sumergidos en el agua 6. Interruptor de voltaje incorrecto La bomba no proporciona agua ni genera presión 7. La empaquetadura del entubado tiene una fuga 1.
GARANTÍA Este producto está garantizado durante un año desde la fecha de compra o durante dos años desde la fecha de fabricación, la que ocurra primero. Sujeto a las condiciones establecidas a continuación, el fabricante ofrecerá al consumidor original la reparación o el reemplazo de cualquier parte del producto que presente un defecto resultante de la mano de obra o materiales defectuosos. Para obtener el servicio de garantía, póngase en contacto con el distribuidor a quien adquirió el producto.
PIEZAS DE REPUESTO No hay piezas de repuesto en garantía disponibles para este producto. Para obtener las piezas de repuesto no amparadas por la garantía que se mencionan a continuación, llame a nuestro Departamento de Servicio al Cliente al 1-866-994-4148, de lunes a viernes de 7:30 a.m. a 5:00 p.m. hora estándar del Este.