Operating Guide
2
PACKAGE CONTENTS
SAFETY INFORMATION
PART DESCRIPTION QUANTITY
A Pump 1
B Garden hose adapter/
check valve
1
C Snap-on strainer 1
Please read and understand this entire manual before attempting to assemble, operate, or install 
the product.
•  NOTE: Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard 
UL778. CSA certied pumps are certied to CSA Standard C22.2 No. 108. (CUS.)
•  For pool cover draining only.
•  Not for use with portable pools
A
B
DANGER
•  FIRE/EXPLOSION HAZARD. 
Pump only clear water. Do not pump ammable or explosive uids such as gasoline, fuel oil, 
kerosene, etc. Do not use in a ammable and/or explosive atmosphere. Failure to follow these 
warnings could result in death or serious injury and/or property damage.
•  RISK OF ELECTRIC SHOCK.  
Always disconnect power source before attempting to install, service, or maintain the pump. 
Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal 
electrical shock could occur.
PERFORMANCE
ITEM
NUMBER
MODEL 
NUMBER
HP
GALLONS PER HOUR AT DISCHARGE HEIGHT 
ABOVE PUMPING LEVEL
MAX LIFT
0 FT. 5 FT. 10 FT. 15 FT.
0955587 148003 1/4 2,400 2,280 1,800 1,320 23 FT.
C
AMPS VOLTS HZ
CORD 
LENGTH
DISCHARGE 
SIZE
3.0 115 60 25 FT. 3/4 IN.