Installation Guide
NX-1700E Card Reader
10
Segment 3 Single Scan Hold Function
Program the functions that are performed when a card is scanned and held at the reader for the duration
of the 2 Scan Hold Time (Location 244, Segment 1). The descriptions of the options are the same as for
Single Scan Function. (Default is 1)
LOCATIONS 1 - 240 SERIAL NUMBERS MAPPING USER CARDS TO USERS
(8 segments of hexadecimal data)
DO NOT EDIT LOCATIONS 1- 240. YOU MAY LOSE THE ABILITY TO
SCAN A CARD!!
LOCATION 241 PROGRAMMING THE X-10 ADDRESS FOR THE SCAN FUNCTIONS
(5 segments of numerical data)
Segment 1
Program a number from 0-15 to represent the corresponding X-10 Module Number from the following
table. (Default is 0)
Module
1
2 3 4 5 6 7 8 9 10111213141516
Seg 1
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Segment 2 Program a number from 0-15 to represent the corresponding X-10 House code from the
following table. (Default is 0)
X-10 ADDRESS CODES
0=A 4=E 8=I 12=M
1=B 5=F 9=J 13=N
2=C 6=G 10=K 14=O
3=D 7=H 11=L 15=P
Segment 3 Single Scan Function
Program the X-10 function that is performed when a card is scanned once. This location only needs to
be programmed if Location 0, Segment 1, Option 7 is set. Use the following table. (Default is 2)
Function # Function
performed
Function # Function
performed
0 All units off 4 Dim
1 All lights on 5 Bright
2On
6 All lights off
3 Off All others Reserved
Segment 4 Double Scan Function
Program the X-10 function that is performed when a card is scanned twice within the 2 Scan Hold Time
(Location 244, Segment 1). The descriptions of the function codes are the same as for Single Scan
Function. This location only needs to be programmed if Location 0, Segment 2, Option 7 is set. Use the
above table. (Default is 3)
Segment 5 Single Scan Hold Function
Program the X-10 function that is performed when a card is scanned and held at the reader for the
duration of the 2 Scan Hold Time (Location 244, Segment 1). The descriptions of the function codes are
the same as for Single Scan Function. This location only needs to be programmed if Location 0,
Segment 3, Option 7 is set. Use the above table. (Default is 2)