User's Manual

GE616 Proximity Reader Last Update August 24, 2005
6
4. Specification
5. Installation
5-1. Mullion/Wall Mount
Drill two 6-32 or M3 holes 3.3"(8.38cm) apart in vertical
and drill one 1/2" hole for the reader cable 1.7"(4.31cm) apart
from the top hole.
(If you have installed electric gang box then skip this step.)
5-2. Put reader cable into the center hole and install the
reader module by using two 6-32 or M3 screws.
5-3. Put bezel into the reader module then push bezel until you
hear the locking sound.
Read Range/Time Up to 4"(10cm) / 30ms
Input Voltage/Current DC 5V ~ 17V, Max. 100mA
Output Format 26 bit Wiegand
External Buzzer
Control Input
Low Active, DC 0 ~ 12V,
Max. 50mA
External LED
Control Input
Low Active, DC 0 ~ 12V,
Max. 50mA
LED/Buzzer
2 Color LED (Red and Green) / Piezo
Buzzer
Color Silver
Operating
Environment
-31 ~ 149(℉℉-35 ~ +65 )℃℃
10~90% Humidity, Non-Condensing
Overall Size (WxHxD) 1.82"x4.81"x0.87"(46x122x23mm)
Weight 0.35lb(160g)