User's Manual

2533-7222-00 5 / 8
Specifications
Power
Three AA batteries
Battery type
1.5 VDC alkaline
Required batteries
Duracell MN1500
Energizer E91
Sensor
Electrochemical
Type
B
Battery Life
1 Year (minimum)
Detector life
10 years
Audible detector
Temporal 4
Detector response
times
70 PPM = 60-240 min.
150 PPM = 10-50 min.
400 PPM = 4-15 min.
Dimensions
4.68 x 2.75 x 1.85 in. (119 x 70 x 47 mm)
Storage temperature
-4 to 140
o
F (- 20 to 60
o
C)
Operating environment
Temperature
Relative humidity
40 to 100
o
F (4.4 to 37.8
o
C)
10 to 95% noncondensing
Regulatory information
Agency Rating
ANSI/UL2075, CSFM
Manufacturing information
Manufactured by:
Kidde Safety UTC CCS
4820 Centennial Blvd., Suite 145
Colorado Springs, CO 80919
FCC Compliance
FCC ID: QPY-CO915FFH
IC: 8303B-CO915FFH
The device complies with part 15 of the FCC Rules as well as
Industry Canada Rules and Regulations license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le
fonctionnement.
WARNING: Any changes or modifications made to this
product not expressly authorized by the manufacturer could void
the user’s right to operate this device.