User Manual
Table Of Contents
- Preface
- Chapter 1 Introduction
- Chapter 2 Planning
- Chapter 3 Installing the system
- UL listed installations
- SIA system requirements
- Central station reporting
- UL Canada listed installations
- California state fire marshall listed installations
- Opening panel cover and chassis
- Mounting the panel
- Connecting hardwired devices
- Wiring a phone line to the panel
- Wiring the power transformer
- Installing X10 modules
- Chapter 4 Programming
- Programming overview
- Menu navigation
- System programming
- Resetting memory to the factory defaults
- Chapter 5 Testing
- Chapter 6 Troubleshooting and support
- Appendix A Specifications and tables
- Index
Simon XT
Installation Manual
74
Table 40. Simon XT system quick reference
a
Control panel Remote touchpad Keyfob Telephone
Level 0: Subdisarm
the system
Enter the master code while the
system is disarmed.
1
Level 1: Disarm
the system
DISARM, <access_code>.1
Level 2: Arm doors
and windows
DOORS+WINDOWS, <access_code>
(if required).
2
Level 3: Arm
motion sensors
MOTIONS, <access_code> (if
required).
3
Level 4: Arm doors,
windows, motions
DOORS+WINDOWS, <access_code>
(if required), MOTIONS.
– –
2 – 3
Activate no delay
DOORS+WINDOWS, DOORS+WINDOWS.
Appends –No Delay to arming level
text.
–
2 – 2
Activate latchkey
MOTIONS, <access_code> (if
required), MOTIONS.
– – –
3 – 3
Activate panic
alarm
Press Fire, Emergency, or Police twice
within 3 sec. or hold it for 2 sec.
+ +
Check system
status
STATUS 0
Toggle chime or
special chime mode
Scroll to Chime or Special Chime,
Enter, toggle On/Off, Enter.
Bypass a sensor
BYPASS, <master_code>, scroll to the
sensor, BYPASS.
Time-activated
lights on/off
Scroll to Light Schedules, Enter, toggle
On/Off, Enter.
Sensor-activated
lights on/off
Scroll to Sensor Lights, Enter, toggle
On/Off, Enter.
Specific light on
Press *, <unit_num>.
– <unit_num>.
* –
<unit_num>.
Specific light off
Press #, <unit_num>.
– <unit_num>.
# –
<unit_num>.
All lights on
To turn on all lights controlled by lamp
modules, press * twice. The panel
displays
All Lights On
.
–
* – *
All lights off
To turn off all lights controlled by lamp
modules, press # twice. The panel
displays
All Lights Off.
–
# – #
a. A minus sign (–) between buttons means press one then the next; a plus sign (+) between buttons means press both simultaneously.
Disarm
ARM
Windows
Doors &
ARM
Sensors
Motion
ARM
Windows
Doors &
ARM
Sensors
Motion
ARM
Windows
Doors &
ARM
Windows
Doors &
ARM
Sensors
Motion
ARM
Sensors
Motion
H
o
ld b
ot
h
for 3 sec.
H
o
ld b
ot
h
for 3 sec.
SYSTEM