Simon XT
Installation Manual
60
Control panel
Test the panel by pressing the buttons as described in Table 28. Table 29 provides a list of the arming levels.
Note: An access code is required when arming if the Secure arming option is on..
Note: Forty key presses for invalid codes (ten invalid 4-digit codes, for example) will cause a system access alarm. The alarm
locks all touchpads, except keyfobs, for 90 seconds.
Table 28. Control panel test sequence
Button Function tested Test Correct result
DOORS +
WINDOWS
The panel arms door and
window sensors.
Press DOORS + WINDOWS a second
time to eliminate the programmed
entry delay.
The button will blink when No entry
delay is on.
MOTIONS The panel will arm motion
sensors.
Press MOTIONS a second time to
turn latchkey on.
The button blinks when latchkey is
on.
DISARM The panel will prompt you to
enter an access code.
Enter the appropriate code. The panel will disarm doors,
windows, and motion sensors.
STATUS Press STATUS button for panel to
display and speak the system status.
POLICE Press and hold or press button twice
quickly to activate a nonmedical,
police, or fire emergency alarm.
FIRE Press and hold or press button twice
quickly to activate a nonmedical,
police, or fire emergency alarm.
EMERGENCY Press and hold or press button twice
quickly to activate a nonmedical,
police, or fire emergency alarm.
Table 29. Arming levels
Arming level Description Indication
0 Subdisarms (master access
and duress codes only), and
bypasses 24-hour intrusion
sensors (master access
code only). Fire sensors
(group 26) cannot be
subdisarmed.
One beep indicates the system is subdisarmed. The panel displays and
speaks Subdisarmed. The DISARM button blinks.
1 Disarm the system One beep indicates the system is disarmed. The panel displays and speaks
Disarmed
. The DISARM button lights.
2 Arm doors and windows Two beeps verify that door/window sensors are armed. The panel displays
Doors + Windows
and speaks
Doors and windows on
. The
DOORS+WINDOWS button lights.
3 Arm motion sensors Three beeps verify that motion sensors are armed. The panel displays
Motions
and speaks
Motions On
. The MOTIONS button lights.
4 Arm doors, windows, and
motion sensors
Four beeps verify that door/window and motion sensors are armed. The
panel displays
Doors + Windows & Motions
and speaks
Doors and
windows on, Motions on
. The DOORS+WINDOWS and MOTIONS buttons
light.