Siren options
Table 23 provides siren option details.
HW 1 function 1 The setting for this option determines how the HW1 I/O output will function.
24-hour clock Off Determines whether the panel uses a 24-hour clock (on) or 12-hour clock (off).
a. Not investigated for use by UL.
Table 23. Siren options
Function Default Description
Piezo beeps On This option determines whether the panel piezo produces beeps based on system
activity (on) or is silent (off).
Panel voice On When On, arming level changes will be spoken.
Panel piezo
alarm
On Determines whether the panel piezo emits alarm sounds (on) or not (off).
Trouble beeps On Determines whether the panel, X10, and hardwired interior sirens sound six beeps every
minute when a trouble condition occurs (on) or not (off). The following conditions cause
trouble beeps:
AC power failure (when AC power failure report is on) low CPU battery
Sensor failure (supervisory)
Sensor trouble (low battery, tamper, etc.)
Fail to communicate
Restoration of power
No Activity timer has timed out. Trouble beeps continue for 5 minutes and if the panel
does not see activity, trouble beeps stop and the panel reports the no activity to the
central station.
Trouble beeps can be silenced by arming or disarming the system or by pressing the
STATUS button. Trouble beeps resume 4 hours later if the trouble condition is not
cleared.
Voice chime Off Determines whether the panel announces the sensor name.
1 = Sensor name
2 = Loud ding-dong bell
3 = Soft ding-dong bell
Off = No sound
Table 22. System options (continued)
Function Default Description
Off = No output.
1 = Interior siren output.
2 = Output activated when armed.
3 = Output activated when disarmed.
4 = Fail to communicate output; activates when fail to communicate condition
occurs (Fail to communicate must be on) two.
5 = Alarm output activated when panel is in alarm