User Manual

Table Of Contents
Chapter 4
Programming
51
Touchpad options
Table 21 provides touchpad option details.
Note: These options have not been investigated by UL..
System options
Table 22 provides system option details.
Smoke
supervision
Off Determines how often the panel must receive supervisory signals from the smoke
sensors. If this option is on, the panel must receive at least one supervisory signal from
smoke sensors every four hours or it will identify a sensor failure and sound trouble
beeps. If this option is off, the time for receiving supervisory signals is determined by RF
Timeout.
a. Not investigated for use by UL.
b. For UL installations, auto phone test must be turned on and set to 24 hours (1 day).
Table 21. Touchpad options
Function Default Description
Keyfob no delay Off Determines whether a keyfob arms the system with no delay (on) or not (off).
When this feature is on, you must disarm the system before entering the premises, since
it is disabling the entry delay. If Remote touchpad arming is on, keyfobs cannot disarm
the system and will cause an alarm upon entering.
Panic alarms On Determines whether the panel panic buttons (police, auxiliary, and fire) activate alarms
when pressed (on) or not (off)
Remote TP arm Off Determines whether keyfobs and remote touchpads can disarm the system only during
exit and entry delays (on) or arm and disarm the system anytime (off). If this option and
Keyfob no delay are on, users cannot enter and/or disarm using remote touchpads
without causing an alarm.
Table 22. System options
Function Default Description
RF jam detect Off Determines whether the panel checks for and reports RF interference/jam to the central
station (on) or not (off). If this option is on and the panel receives a constant 319.5 MHz
signal, the panel reports the condition to the central station. If this option is off, the
panel does not detect an RF jam.
Demo mode
a
Off Determines whether the panel operates as a demonstration model (on) or a standard
panel (off).
Turning on this feature disables low battery supervision and allows the microphone to
remain on continuously during an AVM session. With option on panel is not testing
battery supervision.
Table 20. Timers (continued)
Function Default Description