Note: UL has only verified reporting compatibility with the CS5000 Digital Alarm Communicator Receiver. For UL listed systems,
Phone 1 Report Mode must be set to All SIA or All CID.
Alarms include: Fire, Intrusion, Emergency, Silent, and Alarm Cancels.
Nonalarms include: Latchkey, No Activity, Openings, Closings, Fail to Open, Fail to Close, Force Armed, AC
Power Failure, CPU Low Battery, and Trouble Restorals.
Timers
Table 20 provides timer option details.
Table 19. Communication modes
Function Default Description
Phone 1 report
mode
Off All SIA
All CID
Alarm SIA
Alarm CID
Nonalarm SIA
Nonalarm CID
Backup SIA (phone failure backup)
Backup CID (phone failure backup)
Voice dialer
Off
Phone 2 report
mode
Phone 3 report
mode
Phone 4 report
mode
Table 20. Timers
Function Default Description
Latchkey time
a
Off Determines whether the panel reports a latchkey alarm if the system is not disarmed at
a preset time between midnight and 11:59 P.M. (on). If the latchkey feature is disabled
(off), the panel will not report a latchkey alarm.
The system clock must be set for the latchkey feature to work.
Entry delay 030 seconds Determines how much time the user has to disarm the system after entering the armed
premises through a designated delay door, before an alarm occurs. Beeps sound during
the entire delay time to remind the user to disarm the system.
When turned on, the Entry Delay can be set from 030 to 240 seconds.
Exit delay 060 seconds Determines how much time the user has to leave the premises through a designated
delay door after arming the system. Beeps sound after arming the system to remind the
user to leave the armed premises. If a delay door is opened after the Exit Delay expires,
the Entry Delay begins. If the user arms the system with No Delay and opens a delay
door after the Exit Delay expires, an alarm occurs.
When turned on, the combined dial and entry delay cannot exceed 60 seconds for a UL
Listed installation.