Simon XT
Installation Manual
48
Low CPU battery On Determines whether the panel sends a low CPU battery report to the central station
when the panel backup battery voltage drops
Sen alarm
restore
Off Determines whether the panel reports sensor alarm restorals (on) or not (off). Setting
when restorals are reported:
1. Immediately after sensor is closed or restored after dial delay.
2. After siren timeout expires if sensor is restored.
3. When system is disarmed if sensor is restored.
24-hour sensor
tamper
Off Determines whether the system (armed or disarmed) goes into and reports an alarm
anytime a sensor tamper switch is tripped (on), or only when the system is armed and a
tamper switch of an armed sensor is tripped (off).
Supervisory
tamper
a
Off Determines whether the panel sends supervisory reports to a central station as a
tamper (on) or a supervisory (off).
This option is typically used only in Europe where a supervisory condition is required to
report as a tamper.
No usage
a
Off Determines whether the panel sends a No Usage report to the central station if the user
has not operated the system before the programmed time expires (on) or not (off). The
timer starts each time the system is disarmed.
This is a customer service feature that alerts the central station if a customer is not
using their security system. The service provider can then contact the customer to find
out why the system is not being used, and help correct any problems for the customer.
Swinger
shutdown
On Determines whether the panel prevents the same sensor from activating an alarm more
than once in a single arming period (on) or not (off).
Note: Swinger Shutdown does not affect smoke and fire sensors.
Program report Off Determines whether the panel sends a report to the central station anytime the
programming mode is entered/exited (on) or not at all (off). The panel sends a report
whenever the dealer (Utility 1) or installer (Utility 2) code is used to enter programming
mode and another report is sent when the programming session ends.
Fire verify Off If this option is off, the panel immediately reports to the central station when a smoke
detector goes into alarm.
With this option on, if a single smode detector goes into alarm the panel will not report
for 60 seconds unless another smoke detector goes into alarm. If the first smoke
detector is cleared of alarm with the first 60 seconds, no report will be sent to the
central station unless it or a second smoke detector goes into alarm within the panel
siren timeout period (5 minutes).
a. Not investigated for use by UL.
Table 18. Reporting options (continued)
Function Default Description