Chapter 3
Installing the system
21
Residential fire warning system control unit (ULC-S545-M89)
Basic system as described for UL 985 listed installations plus:
• Wireless smoke sensor 60-848-95 learned into sensor group 26
• Siren timeout set to six minutes or more
• For 24-hour backup, the total current draw for all connected devices is limited to 250 mA (during
normal standby conditions) using a 1.2 AH battery.
California state fire marshall listed installations
Applied for.