Simon XT
Installation Manual
14
Timers menu
Latchkey time
b
None None 12:00 midnight to 11:59 PM,
None
D, I, M
Entry delay (must be 45
seconds for UL listed
systems
30 sec. 30 sec. 30 to 240 sec. D, I
Exit delay (must be 60
seconds for UL listed
systems)
60 Seconds 45 sec. 45 to 254 sec. D, I
No activity timeout
b
Off Off 2 to 24 hours D, I
Auto phone test (must be set
to 1 for UL listed systems)
Off Off 1 to 254 days D, I
Supervisory time Midnight None 12:00 midnight to 11:59 PM,
None
D, I
Alarm cancel 6 minutes Off 6 to 255 minutes, Off D, I
RF timeout (supsync) (must
be set to 4 for UL 985 & 1635
listed systems, or 24 for UL
1023 listed systems)
12 hours 12 hours 2 to 36 hours D, I
Fail to open time
b
Off Off 12:00 midnight to 11:59 PM,
Off
D, I
Fail to close time
b
Off Off 12:00 midnight to 11:59 PM,
Off
D, I
Siren timeout (must be
greater than 4 minutes for
UL listed systems)
5 minutes Off - No timeout 2 to 254 minutes, Off D, I
Arming LED shutdown Off Off On/Off D, I
Unvacated premises On Off On/Off D, I
Smoke supervision (must be
disabled for UL listed
systems)
Off Off On/Off D, I
Touchpad options menu
Keyfob no delay
b
Off Off On/Off D, I
Panic alarms
b
On Off On/Off D, I
Remote touchpad arming
b
Off Off On/Off D, I
Table 6. System programming menu options (continued)
Function Default Delete Range Access
code
a
Installer
settings