Simon XT
Installation Manual
8
15 Instant interior: Interior PIR motion sensors.
a
Intrusion F Y Y 234
16 Instant interior: Interior doors. Intrusion F Y Y 34
17 Instant interior: PIR motion sensors and Sound sensors.
a
Intrusion F N Y 34
18 Instant interior: Cross-zone PIR motion sensors. Intrusion F N Y 34
19 Delayed interior: Interior doors that initiate a delay before going into alarm. Intrusion S Y Y 34
20 Delayed interior: PIR motion sensors that initiate a delay before going into
alarm.
a
Intrusion S N Y 34
21 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion I Y Y 1234
22 Local delayed interior: same as group 21, plus activation initiates a delay
before going into alarm. No report.
a
Intrusion S Y Y 1234
23 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. No report.
b
Emergency I Y Y 01234
24 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. No report.
a
Emergency I Y Y 01234
25 Local special chime: notify the user when a door is opened.
b
Three beeps I N Y 01234
26 Fire: 24-hour fire, rate-of-rise heat, and smoke sensors.
c
Fire I Y Y 01234
27 Lamp control or other customer feature. No report.
b
Silent I Y Y 01234
28 PIR motion sensor, sound sensor, or pressure mat. RF thermostat. No report.
b
Silent I N Y 01234
29 Auxiliary: freeze sensors.
b
Trouble beeps I Y Y 01234
32 PIR motion sensor or sound sensor. No report.
b
Silent I N N 01234
34 Carbon monoxide alarm.
b
Emergency I Y Y 01234
35 Entry/exit delay interior PIR motion. Intrusion S N Y 234
36 Special Intrusion: such as gun cabinets and wall safes. Reports as tamper if
tripped.
b
Intrusion I Y Y 1234
37 Light switch control: X10 modules turn either on or off when a door is opened.
b
Silent I N Y 01234
38 Auxiliary: water sensors.
b
Trouble beeps I Y Y 01234
39 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion I Y Y 1234
40 Local special chime. Three beeps I Y Y 01234
a. This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
b. This type has not been investigated by UL.
c. This type is required for UL-listed residential fire alarm applications.
Table 4. Sensor group characteristics (continued)
Type
Name/application Siren type
Delay
Restoral
Supervisory
Active In
arming
levels