Installation Manual
Table Of Contents
- Sentrol AP750W Wireless PIR Motion Sensor
- Product Summary
- Installation
- Mounting the Motion Sensor
- Setting the Sensor Coverage Area and Sensitivity
- Walk Testing
- Installing Masks
- Programming
- 1. Put the panel into program mode.
- 2. Advance to the learn sensors menu.
- 3. Enter the appropriate sensor group and desired sensor number.
- 4. When the panel prompts you to trip the sensor, activate the sensor tamper switch by removing the sensor cover.
- 5. Reattach the sensor cover.
- 6. Exit from program mode.
- Final Testing
- 1. After the sensor has been mounted, remove the sensor cover to trip the tamper switch and acti vate the walk test mode.
- 2. Replace the sensor cover.
- 3. Place the control panel in test mode.
- 4. Move across the detection pattern until the sensor LED turns on, then STOP your motion.
- 5. Listen for the appropriate system response. If the system does not respond, proceed to the “Troubleshooting” section.
- Maintenance
- Replacing Batteries
- Note Avoid touching the mirror. Fingerprints may affect detection coverage
- 4. Carefully remove the PIR (lower) circuit board by pressing outward on either side tab, then pull up on the circuit board (see Figure 12).
- 5. Remove the PIR circuit board battery (located on opposite side of components) and install a new one, observing polarity (marked on the circuit board).
- 6. Re-install the PIR circuit board into the sensor plastic.
- 7. Re-install the transmitter circuit board onto the PIR circuit board.
- 8. Install a new battery in the transmitter circuit board, observing polarity (marked in battery bucket).
- Lithium Battery Disposal
- Troubleshooting
- Specifications
- Notices
- These devices comply with part 15 of the FCC rules. Operation is subject to the following two conditions:
- 1. These devices may not cause harmful interference.
- 2. These devices must accept any interference received, including interference that may cause undesired operation.
- Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the users’ authority to operate the equipment.
- FCC ID: B4Z-844-PIR
- U.S. Patent Nos: 4,855,713, 4,864,636, 5,761,206, 5,805,063, 5,872,512, and 5,942,981
- Preliminary 9/1/04
6
Sentrol AP750W Wireless PIR Motion Sensor Installation Instructions
Preliminary 9/1/04
Note
Avoid touching the mirror.
Fingerprints may affect
detection coverage
4. Carefully remove the PIR (lower) circuit board by pressing outward on either side tab, then
pull up on the circuit board (see Figure 12).
Figure 12.Removing the PIR Circuit Board
5. Remove the PIR circuit board battery (located on opposite side of components) and install a
new one, observing polarity (marked on the circuit board).
6. Re-install the PIR circuit board into the sensor plastic.
7. Re-install the transmitter circuit board onto the PIR circuit board.
8. Install a new battery in the transmitter circuit board, observing polarity (marked in battery
bucket).
After replacing batteries, wait at least 3 minutes before activating the walk test mode.
Lithium Battery
Disposal
Lithium batteries that are no longer usable are considered hazardous waste. Be sure to properly
dispose of the old batteries. Contact your local city government for hazardous waste disposal
laws.
Troubleshooting Use the following guidelines if the system does not respond correctly when the sensor is acti-
vated.
• Check programming and re-program sensor into panel if necessary.
• Move the sensor to another location and test for correct response.
• Test a known good sensor at the same location.
• If the system does not respond, avoid mounting a sensor at that location.
• If the replacement sensor functions, return the problem sensor for repair or replacement.
P U L L O U T O N
E I T H E R T A B . . .
. . . W H I L E P U L L I N G
T R A N S M I T T E R
B O A R D U P .
M I R R O R