Testing the System
Voice Event Notification
Testing this feature requires two people; one at the alarm site
and the other at the location the panel is programmed to call
(Options 5 and/or 43). The panel only reports alarms when this
feature is set up.
CAUTION!
If the system is monitored by a central station, contact
them first before setting off any alarm s to avoid a false
dispatch.
1. Contact the central monitoring station (if system is
monitored) to inform them you are testing the system
and not to dispatch authorities.
2. At the system site, put the system into an alarm condi-
tion.
3. At the calling location, pick up the phone after it starts
ringing. You should hear the panel voice announce
Press star for alarm.
4. Press
and the panel voice identifies the alarm. If
there is more than one alarm in progress, the panel
voice identifies all of them.
5. After listening to the alarm information, press
ƒ to ter-
minate the call.
Important!
You must terminate the call by pressing ƒ. Otherwise,
the panel may not disconnect from the phone line for up
to 2 minutes.
X-10 Operation
The following sections describe how to test X-10 Lamp, Siren,
Appliance, and Universal Module operation.
Manual Lamp Module Control
Control Panel: Press the Lights On button and the unit #
of the lamp module using the numeric buttons to test indi-
vidual lamp modules 2, 4, 6, and 8. The panel responds
with Lights # on/off.
Press the Lights On button twice to turn on all lamp mod-
ules. Press the Lights Off button twice to turn off all lamp
modules.
Keychain Touchpad: Press the LIGHT button repeatedly
to turn all lights on and off. The panel responds with
Lights on/off.
Remote Handheld Touchpad: Press the Lights On but-
ton and the unit # of the lamp module using the numeric
buttons to test individual lamp modules 2, 4, 6, and 8. The
panel responds with Lights # on/off.
X-10 Siren and Lamp Module Functions
All sirens turn off when the system is disarmed or when the
siren timeout expires. Siren priority is as follows:
1. Fire (highest priority)
2. Intrusion
3. Emergency
If an alarm of greater priority occurs during an alarm of lower
priority, the greater priority alarm sirens sound. Fire alarms
sound a temporal 3 pattern (0.5 seconds on, 0.5 seconds off for
three beeps then 1.5 seconds off).
Note
The X-10 Siren must be set to unit #9 to hear emer-
gency alarms.
Audio Verification Set
Phone
Button(s)
Function
0-1 Speak
2 VOX operation
3 or 6 Listen
7 Extend session for 90 more seconds
88 Terminates session with call back (the panel
answers on the first ring if called within 5
minutes)
99 Terminates session with no call back
Alarm Siren and X-10 Light Information
Fire Intrusion Emergency
X-10 Lights Steady Flashing Steady
X-10 Siren Steady Steady Alarm beeps
Interior &
Panel Siren
Temporal
3
Steady Fast on/off
Exterior Siren Temporal
3
Steady