Owner's Manual

Table Of Contents
25
Programming
Option 70: Not Available
Option 71: Programming Report (Default = off)
Determines whether the panel sends a report to the central sta-
tion anytime the programming mode is entered/exited (on) or
not at all (off).
The panel sends a report whenever the dealer (Utility 1) or
installer (Utility 2) code is used to enter programming mode
and another report is sent when the programming session ends
(when the cover is closed).
To turn on Programming Report, press:
AddOption #71DONE.
To turn off Programming Report, press:
DeleteOption #71DONE.
Option 72: Supervisory Time (Default = 12:00am)
Determines when the panel reports supervisory conditions
(sensor failures) and automatic phone tests to the central sta-
tion.
Note
The panel clock must be set to the correct time for this
option and Option 16: Auto Phone Test to work correctly.
To set Supervisory Time, press:
AddOption #72HoursMinutesDONE.
To turn off (disable) Supervisory Time, press:
DeleteOption #71DONE.
Option 73: Modem Sensitivity (Default = off)
Determines whether the modem sensitivity is set to normal
(off) or high (on).
Note
This feature should be used only if the panel experiences
consistent trouble reporting to the central station. Other-
wise, leave this option off.
To turn on Modem Sensitivity, press:
AddOption #73DONE.
To turn off Modem Sensitivity, press:
DeleteOption #73DONE.
Option 74: Silent Panel Police Panic (Default = off)
Determines whether pressing the panel police panic button
causes an audible (off) or silent (on) alarm.
Note
For UL Listed systems, this option must be off (audible).
To turn on Silent Panel Police Panic, press:
AddOption #74DONE.
To turn off Silent Panel Police Panic, press:
DeleteOption #74DONE.
Option 75: VOX Mic Gain (Default = 14)
Sets the mic gain (sensitivity) that triggers the voice-activated
switching (VOX).
Room size, acoustics, and furnishings where the panel or Inter-
rogator 200 are located will influence the setting. The available
settings are 01 (low) - 64 (high). Entries must be 2 digits.
For panels with a built-in microphone, a setting of 14 is recom-
mended. For systems using the Interrogator 200, a setting of 7
should be used.
To set VOX Mic Gain, press:
AddOption #7501 - 64DONE.
To reset Vox Mic Gain (return to default), press:
DeleteOption #75DONE.
Option 76: VOX Gain Range (Default = 64)
Note
This option works in conjunction with Option 75: VOX Mic
Gain. It is important to follow the setting recommenda-
tions as described to achieve acceptable operation.
Sets the gain range for the voice-activated switching (VOX).
The available settings are 01 (low) - 64 (high). Entries must be
2 digits.
For best results, this option should be set equal to or greater
than Option 75: VOX Mic Gain. For panels with a built-in
microphone, this option should be set to the default value.
To set VOX Gain Range, press:
AddOption #7601 - 64DONE.
To reset VOX Gain Range (return to default), press:
DeleteOption #76DONE.
Option 77: Manual Mic Gain (Default = 64)
Determines the gain level (sensitivity) during 2-way audio ses-
sions, when Option 33: Audio Verification is set to 0 or 1
(Speak).
Room size, acoustics, and furnishings where the panel or Inter-
rogator 200 are located will influence the setting. The available
settings are 01 (low) - 64 (high). Entries must be 2 digits.
For panels with a built-in microphone, a setting of 64 is recom-
mended. For systems using the Interrogator 200, a setting of 20
should be used.
To set Manual Mic Gain, press:
AddOption #7701 - 64DONE.
To reset Manual Mic Gain (return to default), press:
DeleteOption #77DONE.