Owner's Manual

Table Of Contents
22
Programming
To turn on 24 Hour Tamper, press:
AddOption #51DONE.
To turn off 24 Hour Tamper, press:
DeleteOption #51DONE.
Option 52: Unvacated Premises (Default = on)
Determines whether the system automatically arms down to
level 2 (ARM Doors & Windows) if the user arms the system
to a higher level without leaving the premises (on), or remains
at the armed level chosen by the user (off).
Note
This feature does work from a keychain touchpad.
If this option is turned on and the user arms to level 3 (ARM
Motion Sensors) or 4 (ARM Doors & Windows, + ARM
Motion Sensors) but does not exit the premises within the Exit
Delay time, the panel automatically changes to arming level 2.
Note
Option 38: Auto Arm must be on for this feature to work.
To turn on Unvacated Premises, press:
AddOption #52DONE.
To turn off Unvacated Premises, press:
DeleteOption #52DONE.
Option 53: Hardwire Siren Supervision
(Default = off)
Determines whether the panel monitors hardwired sirens for
open or shorted conditions (on), or not (off).
If this option is turned on, sirens connected to the panel termi-
nals require an EOL resistor in the wire circuit (see Installing
the System for siren supervision wiring). If this option is
turned off, EOL resistors are not required whether sirens are
connected or not.
Note
For UL listed systems, this feature must be on and EOL
resistors installed. Also for UL Listed systems, this fea-
ture must be on if Option 29: Panel Piezo Alarms is off.
To turn on Hardwire Siren Supervision, press:
AddOption #53DONE.
To turn off Hardwire Siren Supervision, press:
DeleteOption #53DONE.
Option 54: Access Code Length (Default = 4)
Determines how many digits are in all access codes.
Turning on this option lets you set the access code length to 3,
4, 5, or 6 digits. Turning off this option resets the access code
length to the default setting, resets Master, Utility 1, and Utility
access codes.
Read the following before changing this option.
This option affects all system access codes (Master, Util-
ity 1, Utility 2, Panic, and User).
Changing the access code length changes the Master, Util-
ity 1, and Utility 2 access codes to their respective defaults
as described in the following table.
Note
Changing the Access Code Length clears/deletes any
User Codes that were previously programmed. If the cus-
tomer wants the Access Code Length changed, it should
be set before programming any new (unprogrammed)
access codes, whenever possible
To change Access Code Length, press:
AddOption #543, 4, 5, or 6DONE.
To reset Access Code Length (to default), press:
DeleteOption #54DONE.
Option 55: Status Beep Volume (Default = 07)
Determines the panel piezo volume level for status sounds such
as arming, trouble, and status beeps.
The volume can be set from 1 (lowest) to 10 (highest). Turning
off this option resets the volume to the default setting. Entries
must be 2 digits.
To set Status Beep Volume, press:
AddOption #5501 - 10DONE.
To reset Status Beep Volume (return to default), press:
DeleteOption #55DONE.
Option 56: Call Waiting (Default = off)
Lets you program up to a 26-digit number or code that disables
call waiting or any other phone service before dialing central
station, pager, or voice event notification phone numbers (on).
When this option is turned off, the panel dials only the central
station or pager phone numbers.
Press Test for each required pause, Add for a *, and Delete for
a # (each of which uses one of the 26 available places).
Access Code Length Defaults
Setting Default Code
3Master123
Utility 1321
Utility 2321
4Master1234
Utility 14321
Utility 24321
5Master12345
Utility 154321
Utility 254321
6Master123456
Utility 1654321
Utility 2654321