User's Manual
Table Of Contents
- Part No. 60-982-95R
- Dialog QS1000
- Allegro Remote Station
- Product Summary
- Programming
- 1. Enter the appropriate code to access the panel menus.
- 2. Enter the panel Learn/Add Sensors/Devices menu.
- 3. Change the sensor number if necessary.
- 4. Press and hold both Police Panic buttons on the remote station.
- 1. Press and hold the 8 button. The remote station will beep every 2 seconds.
- 2. Release the button when the desired volume is reached.
- Mounting
- Figure 1. Tab location
- 1. Remove the remote station from the back mounting plate by lifting the tab located on the top and pulling back.
- 2. Remove the wiring knockout.
- 3. Feed all device wires through the knockout and place the back mounting plate in position against the wall.
- 4. Level the back mounting plate and mark the top and bottom mounting holes.
- 5. Install anchors where studs are not present.
- 6. Partially insert a screw into the top mounting hole location then hang the back mounting plate on the screw.
- 7. Recheck for level, insert the lower screw, and tighten both mounting screws.
- 8. Install the antenna. There are three antenna options to choose from:
- 9. Place the remote station cabinet into the back mounting plate and snap into place.
- Connecting Detection Devices to the remote station
- Important ! The 2.2 kOhm EOL resistor must be installed across termi nal 3 and 4 even when no detection device is connected. If this is not done the panel will indicate the zone is open.
- Connecting the AC Power Transformer
- Connecting the Backup Battery Pack
- Figure 5. Connecting the Battery Pack
- 1. Remove the panel housing from the back mounting plate by lifting the tab located on the top of the remote station and pulling back.
- 2. Slide the battery pack into the space provided on the back of the remote station (Figure 5).
- 3. Plug the battery pack lead into the slot provided next to the wire terminals (Figure 5).
- 4. Replace the remote station housing on the back mounting plate and snap into place.
- Powering Up the Remote Station
- Specifications
- Notices
4
Allegro Remote Station Installation Instructions
Preliminary 9/19/03
Specifications Model No.: ................................60-982-95R
Compatibility: ..........................Allegro™ Software Version 1.3 and later
RF Frequency:..........................319.5 + or - 140 kHz
Power Source: .........................8 or 9 VAC, minimum 300 mA (Must be a GE Interlogix recommended
transformer.)
Battery Type:............................4.8 VDC rechargeable NiCd battery pack
Typical Standby Current:........
Operating Temp Range: ..........32° to 122° F (0° to 49° C)
Storage Temp Range:...............-30° to 140° F (-34° to 60° C)
Relative Humidity:...................90% non-condensing
Dimensions (in): .......................7.5 x 6.75 x 1.5 (L x W x D)
Weight (lb):...............................1.0
Installation: ..............................Wall mount
Nominal Range:........................500 Feet, (150 m) open-air receiving range
Notices This device complies with FCC Rules Part 15. Operation is subject to the following two conditions.
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference that may cause undes-
ired operation.
Changes or modifications not expressly approved by GE Interlogix can void the user’s authority to operate the
equipment.
FCC ID: B4Z-785B-ALTP
2266 Second Street North
North Saint Paul MN 55109
Technical Support: 800-777-2624
)
*(,QWHUORJL[
©2003 GE Interlogix. Dialog and Allegro are trademarks of GE Inter-
logix. All other trademarks are properties of their owners.
All rights reserved.