- Product Summary
- Programming
- 1. Enter the appropriate code to access the panel menus.
- 2. Enter the panel Learn/Add Sensors/Devices menu.
- 3. Change the sensor number if necessary.
- 4. Press and hold both Police Panic buttons on the remote station.
- 1. Press and hold the 8 button. The remote station will beep every 2 seconds.
- 2. Release the button when the desired volume is reached.
- Mounting
- Figure 1. Tab location
- 1. Remove the remote station from the back mounting plate by lifting the tab located on the top and pulling back.
- 2. Remove the wiring knockout.
- 3. Feed all device wires through the knockout and place the back mounting plate in position against the wall.
- 4. Level the back mounting plate and mark the top and bottom mounting holes.
- 5. Install anchors where studs are not present.
- 6. Partially insert a screw into the top mounting hole location then hang the back mounting plate on the screw.
- 7. Recheck for level, insert the lower screw, and tighten both mounting screws.
- 8. Install the antenna. There are three antenna options to choose from:
- 9. Place the remote station cabinet into the back mounting plate and snap into place.
- Connecting Detection Devices to the remote station
- Important ! The 2.2 kOhm EOL resistor must be installed across termi nal 3 and 4 even when no detection device is connected. If this is not done the panel will indicate the zone is open.
- Connecting the AC Power Transformer
- Connecting the Backup Battery Pack
- Figure 5. Connecting the Battery Pack
- 1. Remove the panel housing from the back mounting plate by lifting the tab located on the top of the remote station and pulling back.
- 2. Slide the battery pack into the space provided on the back of the remote station (Figure 5).
- 3. Plug the battery pack lead into the slot provided next to the wire terminals (Figure 5).
- 4. Replace the remote station housing on the back mounting plate and snap into place.
- Powering Up the Remote Station
- Specifications
- Notices
2
Allegro Remote Station Installation Instructions
Preliminary 9/19/03
Note
The wiring knockout is
approximately the same
width as a wall stud. If
mounting the remote station
to a wall stud be sure you
have enough room to feed
the wires through the knock-
out.
5. Install anchors where studs are not present.
6. Partially insert a screw into the top mounting hole location then hang the back mounting
plate on the screw.
7. Recheck for level, insert the lower screw, and tighten both mounting screws.
8. Install the antenna. There are three antenna options to choose from:
• Standard Range- Leave the antenna as is.
• Extended Range - Attach the optional antenna housing (included in the accessory
pack) to the remote station.
a.Push the antenna housing down into the top right hole of the remote station until it
snaps into place (see Figure 2).
b.Remove the antenna loop from the last clip on the remote station cabinet and insert
it into the antenna housing.
• Longest Range - Hang the antenna in the wall.
a.When you mark the back mounting plate’s two mounting holes, also mark where
the antenna hole is (see Figure 2 for antenna wire hole location).
b.Where the antenna hole was marked, drill a hole into the wall.
c.Remove the antenna loop (see Figure 2) from the remote station cabinet clips and
feed through the antenna hole and down into the wall.
Figure 2. Antenna configurations
9. Place the remote station cabinet into the back mounting plate and snap into place.
Connecting Detection Devices to the
remote station
The remote station has one hardwire input. The input is
supervised using a 2.2 k Ohm, end-of-line (EOL) resis-
tor (included with the remote station) at the last device
on the circuit. It accepts normally closed (N/C) detec-
tion devices. Figure 3 shows the typical wiring for a N/
C door/window intrusion detection.
The maximum loop resistance for each zone input is
300 ohms, plus the 2.2 k Ohm EOL resistor.
Important !
The 2.2 kOhm EOL resistor must be installed across termi-
nal 3 and 4 even when no detection device is connected. If
this is not done the panel will indicate the zone is open.
Clips
Antenna
Loop
6 0 8 7 4 9 5 g 0 2 a . d s f
Antenna
Housing
Push Down
Into Panel
Antenna Wiring
Optional Antenna Housing
Antenna
Wire Hole
Wire
Clip
Mounting
Knockout
Tamper
Switch
Holes
Wiring Hole (Longest Range)
(Extended Range)
(Standard Range)
Panel Terminals
Normally
Closed
(N/C)
Contacts
In Series
3 4
Figure 3. Wiring N/C Intrusion
Detection devices
2.2 k Ohm
EOL Resistor
49-467