Install Manual

Table Of Contents
23
Allegro
Preliminary 2/5/02
Appendix B: Reference Tables
Table B1: Sensor Group Characteristics
No. Name Application Alarm Delay
Restoral
Supervisory
CS Report
Chime
Active
Levels
00 Fixed Panic
24-hour audible fixed emergency buttons.
Police Instant
1, 2, 3
01 Portable Panic
24-hour audible portable emergency buttons.
Police Instant
1, 2, 3
02 Fixed Panic
24-hour silent fixed emergency buttons.
Silent Instant
1, 2, 3
03 Portable Panic
24-hour silent portable emergency buttons.
Silent Instant
1, 2, 3
04 Fixed Emergency
24-hour emergency sensor, such as Pendant Panic or
holdup button.
Emergency Instant
1, 2, 3
06
Portable
Emergency
24-hour portable emergency alert button.
Emergency Instant
1, 2, 3
08 Special Intrusion
Special belongings, such as gun cabinets and wall
safes.
Police Instant
1, 2, 3
09 Special Intrusion
Special belongings, such as gun cabinets and wall
safes.
Police Standard
1, 2, 3
10 Entry/Exit Delay
Entry and exit doors that require a standard delay time.
Police Standard
2, 3
13 Instant Perimeter
Exterior doors and windows.
Police Instant
2, 3
14 Instant Interior
Interior doors.
Police Follower
2, 3
15 Instant Interior
Interior PIR motion sensors. *
Police Follower
2, 3
16 Instant Interior
Interior doors.
Police Follower
3
17 Instant Interior
PIR motion sensors. *
Police Follower
3
18 Instant Interior
PIR motion sensors subject to false alarms. *
Police Follower
3
19 Delayed Interior
Interior doors that initiate a delay before going into
alarm. *
Police Standard
3
20 Delayed Interior
PIR motion sensors that initiate a delay before going
into alarm.
*
Police Standard
3
21 Local Instant
Interior
24-hour local alarm zone protecting anything that
opens and closes.
Police Instant
1, 2, 3
22 Local Delayed
Interior
Same as group 21, plus activation initiates a delay
before going into alarm.
Police Standard
1, 2, 3
23 Local Instant
Emergency
24-hour local alarm zone protecting anything that
opens and closes.
Emergency Instant
1, 2, 3
25 Local Special
Chime
Notify the user when a door is opened. Sounds emit
from a local annunciator. *
Note
If using a PIR motion sensor, use only ITI part no.
60-511-01-95.
Special
Chime
Instant
1, 2, 3
26 Fire 24-hour fire, rate-of-rise heat, and smoke sensors. Fire Instant
1, 2, 3
34 Gas Carbonmonoxide (CO) Gas Detectors Emergency Instant
1, 2, 3
36 DTIM Dialog Telephone Interface Module (DTIM) a Police Instant
1, 2, 3