Install Manual
Table Of Contents
- Appendix B: Reference Tables
- About This Manual
- Special Installation Requirements
- Planning the Installation
- Installing the System
- The panel must be mounted at least 10 feet from any DTIM or between any two DTIMs.
- Mounting the Panel
- 1. Remove the panel from the back mounting plate by lifting the tab located on the top and pullin...
- 2. Remove the wiring knockout.
- 3. Feed all device wires through the knockout and place the back mounting plate in position again...
- 4. Level the back mounting plate and mark the top and bottom mounting holes.
- 5. Install anchors where studs are not present.
- 6. Partially insert a screw into the top mounting hole location then hang the back mounting plate...
- 7. Recheck for level, insert the lower screw, and tighten both mounting screws.
- 8. Install the antenna. There are three antenna options to choose from:
- 9. Place panel cabinet into back mounting plate and snap into place.
- Connecting Detection Devices to Panel Zone Inputs
- Connecting the AC Power Transformer (22-117)
- Connecting the Backup Battery Pack
- Figure 7. Connecting the Battery Pack
- 1. Remove the panel housing from the back mounting plate by lifting the tab located on the top of...
- 2. Slide the battery pack into the space provided on the back of the panel (Figure 8).
- 3. Plug the battery pack lead into the slot provided next to the wire terminals (Figure 7).
- 4. Replace the panel housing into back mounting plate and snap into place.
- Powering Up the Panel
- Programming the Panel
- Mounting the Panel
- Do not wait more than 1-2 seconds between steps 5 and 6 or steps 6 and 7 after releasing the tamp...
- Figure 10. DTIM Tamper Switch and LED Locations
- 1. Remove the DTIM cover.
- 2. Press twice and # once. The display shows phones; devices; add.
- 3. Press #. The display shows zone 01 - trip.
- 4. Press the DTIM’s tamper switch three times, holding the tamper switch down on the third press ...
- 5. Press the DTIM tamper switch twice, holding the tamper switch down on the second press and wai...
- 6. Press and hold the tamper switch down until the LED flashes once. The panel beeps once indicat...
- Account Menu (1st Tier)
- Phones Menu (1st Tier)
- Number 1 and 2 (Phones—Phone 1 and Phone 2)
- 3rd Tier
- FMT - CID (Phones—Phone 1 and Phone 2)
- 3rd Tier
- High Lvl (Phones—Phone 1 and Phone 2)
- 3rd Tier
- Low Lvl (Phones—Phone 1 and Phone 2)
- 3rd Tier
- Openings (Phones—Phone 1 and Phone 2)
- 3rd Tier
- Closings (Phones—Phone 1 and Phone 2)
- 3rd Tier
- Backup (Phones—Phone 2)
- 3rd Tier
- Dial Dly (Phones)
- 2nd Tier
- Pre-Dial String (Phones)
- 2nd Tier
- DTMF Dial (Phones)
- 2nd Tier
- Devices (1st Tier)
- Table 2: Sensor Group Assigned to Device
- Table 3: Device Programming
- Add (Devices)
- 2nd Tier
- Delete (Devices)
- 2nd Tier
- Review (Devices)
- 2nd Tier
- Text (Devices)
- 2nd Tier
- 1. To select the zone you want to add text to press , till you get to the correct zone then press...
- 2. Press # then to scroll thru the base words, press # to select the word you want.
- 3. Press to change to the prefix words. Press # then to scroll thru the prefix words. Press # to ...
- 4. Press to change to the suffix words. Press # then to scroll thru the suffix words. Press # to ...
- 5. Press * to review what has been selected, then press to go to the next zone to change.
- 6. Repeat steps 2 thru 4 to change all zones.
- Table 4: Sensor Text
- Downloader (1st Tier)
- Codes (1st Tier)
- Timers (1st Tier)
- Fire related trouble beeps are not affected by Sleepy Time.
- Sleep Hour (Timers)
- 2nd Tier
- Options (1st Tier)
- KTP Arm (Options)
- 2nd Tier
- Police Panic (Options)
- 2nd Tier
- Emergency Panic (Options)
- 2nd Tier
- Fire Panic (Options)
- 2nd Tier
- Rcvr Trouble (Options)
- 2nd Tier
- Panel Tamper (Options)
- 2nd Tier
- Exit Ext (Options)
- 2nd Tier
- Swinger Shutdown (Options)
- 2nd Tier
- Quick Arm (Options)
- 2nd Tier
- Quick Exit (Options)
- 2nd Tier
- Auto Stay Arm (Options)
- 2nd Tier
- Supv Time (Options)
- 2nd Tier
- Alarm Verify (Options)
- 2nd Tier
- Demo Kit (Options)
- 2nd Tier
- Reports (1st Tier)
- Siren (1st Tier)
- Exit - DL (1st Tier)
- User Programing Menu Items
- Downloader Programming
- ToolBox Downloader Programming
- 1. Contact your downloader station and ask the operator to prepare to download to the panel.
- 2. Make sure the system is disarmed.
- 3. Go into installer program mode.
- 4. Press * to go to the exit - dl display.
- 5. Enter the installer or dealer code.
- 6. When the downloader session completes, a panel programmed status message will be displayed.
- 1. Call the panel location.
- 2. Let the phone ring once, then hang up.
- 3. Wait at least 10 seconds but not more than 40, then call the panel location again. The panel s...
- ToolBox Downloader Programming
- Testing the System
- Allegro
- Appendix A: Troubleshooting
- 1. Check that panel transformer is plugged into an unswitched outlet.
- 2. Check the AC circuit breaker to be sure the circuit is live.
- 3. Check that the backup battery is installed correctly and the AC power transformer is plugged in.
- 4. Check for proper panel and transformer wiring.
- 5. Measure the incoming AC voltage at panel terminals 1 and 2. It should read about 8 VAC.
- 1. Unplug the AC power transformer and disconnect the wires from the transformer and the panel.
- 2. Check transformer to panel wire for short or open circuits.
- 3. Plug in the transformer and check for 8.0 VAC at the transformer unconnected terminals. If zer...
- 1. Perform a battery test by entering and exiting sensor test.
- 2. Check that the backup battery is installed correctly and the AC power transformer is plugged in.
- 3. Measure the incoming AC voltage at the panel terminals 1 and 2. It should read about 8 VAC.
- 4. Remove the backup battery power by disconnecting the battery and replace the battery.
- 1. Check the AC circuit breaker to be sure the circuit is live.
- 2. Check for proper panel and transformer wiring.
- 3. Check that the transformer is supplying AC to the panel.
- 4. Check that the transformer is plugged into a nonswitched outlet and secured with the provided ...
- 1. Check your records to see if you have the customer’s access code(s) on file.
- 2. Verify the access code(s) using the Downloader.
- 3. Clear memory and reprogram the panel locally.
- 4. Use Apartment Manager code to enter program mode and view the primary and user codes.
- 1. Check your records to see if you have the install code on file.
- 2. Verify the install code using the Downloader.
- 3. Use the Dealer Code to enter program mode and view the installer code.
- 4. Call Technical Support for assistance.
- 1. Press STATUS for an indication of the problem.
- 2. Make sure all monitored perimeter doors and windows are closed.
- 3. Make sure all perimeter and interior sensors are closed.
- 1. Attempting to bypass a 24-hour sensor (a sensor that is active in all levels) that cannot be b...
- 2. Sensor is not active in the current arming level.
- 3. Sensor is not learned in.
- 1. Check that the premises phone line is working.
- 2. Perform a phone test.
- 3. Check for correct phone line wiring between the DTIM and RJ-31X Jack (see DTIM Installation In...
- 4. Verify that central station phone number is programmed into the panel. If necessary, reprogram...
- 5. Verify that the correct phone format (SIA or CID) is being used.
- 1. Sensor is not active in current arming level. Verify sensor group and retest.
- 2. Zone is not learned into panel memory. Enter installer program mode. Go to Devices, then Add a...
- 3. Verify wiring.
- 1. Check that the wireless sensor battery is installed.
- 2. Check the sensor battery for low voltage. Replace batteries, if necessary.
- 3. Use an RF Sniffer (60-401) to verify that sensor is transmitting.
- 4. Constant beeps from the RF Sniffer indicate a runaway (faulty) sensor. Remove the sensor’s bat...
- 5. Sensor is not learned into panel memory. Enter installer program mode—Devices, Add, and learn ...
- 6. Sensor may be out of range. Move sensor to another location.
- 1. Sensor tamper switch is tripped—sensor cover is off, not latched securely, or sensor is not mo...
- 2. Check the sensor battery for low voltage. Replace batteries, if necessary.
- 1. Use an RF Sniffer (60-401) to verify that sensor is transmitting. If sensor is not transmittin...
- 2. Change mounting position of sensor (from horizontal to vertical or vice versa) and test sensor...
- 3. Sensor signal is not reaching panel/receiver because sensor is too far away or there is too mu...
- 1. Perform a sensor test.
- 2. Call technical support for assistance.
- 1. Replace the battery and perform a sensor test.
- 2. Call technical support.
- 1. Perform a phone test.
- 2. Check to make sure manual phone test option is on.
- 3. Verify that high and/or low level reporting option is on.
- 4. Perform a sensor test to verify communication between the DTIM and panel. See Phone Test (Repo...
- 5. Check DTIM wiring (see DTIM installation instructions).
- 1. Verify Downloader Phone Number matches ToolBox setting.
- 2. Verify Downloader CODE matches ToolBox setting.
- 3. Verify Dealer CODE matches ToolBox setting.
- 4. Verify panel Account Number matches ToolBox setting.
- 1. Verify Downloader Phone Number matches ToolBox setting.
- 2. Verify Downloader CODE matches ToolBox setting.
- 3. Verify Dealer CODE matches ToolBox setting.
- FCC Notices
- Specifications
- Appendix A: Troubleshooting
9
Allegro
Preliminary 2/5/02
Note
Some combinations of the sensor text selections are too
long for the display.
Delete (Devices)
2nd Tier
(Default = none) The following procedure describes how to
remove hardwire and wireless sensors from panel memory.
Note
Deleting zones/sensors does not delete text associated
with the deleted zone/sensor number.
To delete a device:
1. To select a different zone press to scroll thru the learned
zones. Press
# to delete the displayed zone. The display
shows the next sensor.
2. Repeat step 1 until all desired zones are deleted.
Review (Devices)
2nd Tier
(Default = none) This allows you to view the zone number and
the group for each learned zone or sensor. For example, the
display shows:
ZONE
01 GRP 10
where:
ZONE 01 = zone/sensor number,
GRP 10 = sensor group 10.
Review devices allows the installer to change the group
assigned to devices. The panel accepts the group numbers
defined in Table B1 in Appendix B.
To review a device:
1. To select a different zone press to scroll thru the learned
zones. The display shows the current setting.
2. Enter the desired group number to modify then press #. The
display shows the new setting.
Text (Devices)
2nd Tier
(Default = none) The panel allows sensor text to be associated
with each device. The sensor text consists of a prefix field,
base field, and suffix field. Table 4 shows the words available
for each field. The default text for zones 1-3 are:
❑ Zone 1 - Phone Module (DTIM)
❑ Zone 2 - Front Door
❑ Zone 3 - Back Door
To add text:
1. To select the zone you want to add text to press , till you
get to the correct zone then press
#. Base is the first to be
displayed.
2. Press # then
to scroll thru the base words, press # to
select the word you want.
3. Press to change to the prefix words. Press
# then to
scroll thru the prefix words. Press # to select the word you
want.
4. Press
to change to the suffix words. Press # then to
scroll thru the suffix words. Press # to select the word you
want.
5. Press
* to review what has been selected, then press to
go to the next zone to change.
6. Repeat steps 2 thru 4 to change all zones.
Table 4: Sensor Text
Prefix Field Base Field Suffix Field
None None None
North Keychain Door
NE Touchpad Window
East Front Remote
SE Back Smoke
South Garage Emergency
SW Bedroom Motion
West Guest Room Fire
NW Childs Room Freeze
Utility Room CO
Living Room 0
Dining Room 1
Bathroom 2
Laundry Room 3
Kitchen 4
Office 5
Den 6
Special Chime 7
Basement 8
Upstairs 9
Downstairs
Hallway
Medicine Cabinet
Closet
Attic
System Panic
Phone Module