User's Manual
Table Of Contents
- Product Summary
- Tools Needed
- Installation Guidelines
- Installation
- 1. Decide if the sensor should be mounted horizontally or vertically by locating the alignment ma...
- 2. Remove the sensor cover by squeezing the cover ends firmly to release the tab on the cover fro...
- 3. Remove the circuit board from the sensor base by pulling back the plastic tab and lifting the ...
- 4. Remove the unused reed switch, clipping the leads as close to the board as possible (see Figur...
- 5. Mount the sensor base with screws or brads. Use spacers to compensate for metal surfaces or he...
- 6. Remove the magnet from its base. Mount the magnet base no more than 3/8 inches away from the s...
- 7. Reattach the circuit board to the sensor base.
- 8. Reattach the sensor cover to the sensor base.
- Connecting External Switches
- Programming
- 1. Set the panel to the program mode.
- 2. Proceed to the LEARN SENSORS menu.
- 3. Select the appropriate sensor group and sensor number assignments.
- 4. Set the external switch (if one is connected) in the alarm condition (open for normally closed...
- 5. Trip the sensor’s tamper switch by removing the sensor cover.
- 6. Exit program mode.
- 7. Place the cover back on the sensor.
- Testing
- Specifications
- Notices
- Door/Window & Long Life Door/Window Sensors
2
Door/Window & Long Life Door/Window Sensors
Connecting External Switches
*Ài>À ÞÊ£äÉÓÎÉ
4. Remove the unused reed switch, clipping the leads as
close to the board as possible (see Figure 2.)
Figure 2. Door/Window Sensor Circuit Boards
5. Mount the sensor base with screws or brads. Use spac-
ers to compensate for metal surfaces or height varia-
tions.
6. Remove the magnet from its base. Mount the magnet
base no more than 3/8 inches away from the sensor
base (see Figure 3). Replace magnet cover.)
Figure 3. Mounted Sensor and Magnet
Ìi
Mount the magnet so it won’t interfere with door or
window openings. Do not use two-sided tape.
7. Reattach the circuit board to the sensor base.
8. Reattach the sensor cover to the sensor base.
Connecting External Switches
Door/window sensors can be connected to either normally
open (close on alarm) or normally closed (open on alarm)
external switches. Wire multiple, normally closed switches
in series. Wire multiple, normally open switches in parallel.
Do not attempt to use the built-in reed switches and an
external switch on the same door/window sensor. For high
security installations, always remove both reed switches
when connecting an external switch to the sensor terminals.
Ìi
In UL listed installations, only the normally closed con-
figuration can be used.
Materials Needed
q Hermetically sealed external switches (sealed reed
switch) that supply a minimum 250-millisecond open
or closure on alarm.
q Stranded 22-gauge wire.
q Installation Guidelines
q Do not use solid core wire.
q Do not use mechanical switches.
TA M PER SW ITC H
TERM INALS
CIRCUIT
BOARD
H O LD IN G TA B
REED SW ITCHES
8867G 05A .D S F
3.6 V O LT
1/2 A A B A TTE R Y
M O D E L 60-362
JUM PER
TA M PER SW ITC H
TERM INALS
CIRCUIT
BOARD
H O LD IN G TA B
REED SW ITCHES
3.6 VOLT AA BATTERY
8867G 04C .D S F
M O D E L 60-641
DOOR
DOOR FRAME
MAGNET
SENSOR
8867G02A.DS4
ALIGNMENT MARKS