User's Manual
Table Of Contents
- Product Summary
- Component
- Function
- Wire Gauge (Unshielded or Shielded)
- Max. Wire Length Between Module and Concord Panel
- Figure 2. Mounting on or Near Metal
- Tools and Supplies
- Installation
- Figure 3. Removing the Cover
- To mount the module on a wall:
- 1. Remove the panel AC power transformer and disconnect the backup battery.
- 2. Remove the module cover and set it aside (Figure 3).
- 3. Hold the base against the mounting surface and mark the three mounting holes (Figure 1). Remem...
- 4. Drill holes and insert the appropriate anchors.
- 5. Secure the back-plate to the wall with included panhead screws.
- To mount the module in a Concord panel cabinet:
- 1. Remove the panel AC power transformer and disconnect the backup battery.
- 2. Remove and discard the module cover (Figure 3).
- 3. Insert a support standoff shown in Figure 4 (supplied with panel) into the panel circuit board...
- 4. Slide the module back-plate into the two top mounting clips located on the top-right side of t...
- 5. Push the lower-left corner of the module onto the support standoff (see detail in Figure 5).
- Connecting the Antennas to the Module
- Concord Panel Wiring
- Installing an Optional Cover Tamper Switch
- To install the tamper reed switch (Figure 7):
- 1. Slide the reed switch into the reed switch holder located on the module back-plate as shown in...
- 2. Insert the magnet into the nibs on the module cover. Remove the magnet clip from the module ba...
- 3. Connect the normally closed reed switch (in series with a 2.0K ohm EOL resistor) to the desire...
- To install the tamper reed switch (Figure 7):
- Setting the Unit Number
- Power Up and Bus Communication
- To power up the panel and receiver module:
- 1. Verify that all wiring at the panel, touchpad, and receiver is correct.
- 2. Connect the panel backup battery and plug in the panel AC power transformer.
- 3. Verify that the receiver module status LED is on.
- 4. If desired, enter panel program mode to verify unit number exists (see panel Installation Inst...
- Changing the Receiver Module Unit Number (software versions 1.0–1.6)
- To change the receiver module unit number:
- 1. Remove panel AC power transformer and backup battery.
- 2. Change the DIP switch setting on the module (see Figure 8). Remember, the setting must be diff...
- 3. Connect the panel backup battery and plug in the AC power transformer. The panel automatically...
- 4. The system may still indicate a bus failure if the panel learned a unit number that is no long...
- 5. Exit from program mode. The touchpad and all other bus devices should operate correctly and an...
- Replace Module Cover/Close Cabinet
- To power up the panel and receiver module:
- Programming
- Testing
- Troubleshooting
- Problem
- Action/Solution
- 1. Check for incorrect wiring connections.
- 2. Make sure the panel AC power transformer is plugged in and the backup battery is connected.
- 3. If the LED still remains off, replace the module.
- 1. Verify that the panel recognizes the module by entering program mode (see specific panel Insta...
- 2. Check for incorrect wiring connections.
- 3. Check receiver antenna connections.
- 4. Check for receiver antenna proximity to metal obstructions such as ducting or AC wiring.
- 5. If the LED still doesn’t flash, replace the module.
- 1. Check that no bus devices are set to the same unit number.
- 2. Change the module unit number and re-initialize the panel/module by disconnecting and reconnec...
- 1. Make sure that the wireless zone capabilities of the module and panel have not been exceeded. ...
- 2. If the system still doesn’t respond, replace the module.
- Specifications
- Notices
2
Installation Guidelines
Installation Guidelines
Observe the following guidelines when installing the
receiver module:
❑ Concord
™
systems can accommodate a maximum of
76 wireless sensors/zones.
❑ In Concord systems, up to 16 SuperBus 2000 devices
can be connected to the panel (SuperBus 2000 Touch-
pads, Receivers, HIMs, HOMs, ESMs, etc.).
❑ Each bus device must have a different unit number.
❑ Leave 10-inches above the module for the antennas.
❑ If mounting the module inside the panel cabinet, use a
support standoff included with the Concord panel.
If mounting the module away from the panel, use the
wire length guidelines in Table 2.
❑ Avoid areas that are likely to expose the module to
moisture.
❑ Avoid areas with excessive metal or electrical wiring,
including furnace and utility rooms.
If unavoidable, mount on or near metal with the anten-
nas extending above the metallic surfaces, as shown in
Figure 2.
Figure 2. Mounting on or Near Metal
Tools and Supplies
❑ Screwdrivers
❑ Drill with bits
❑ Mounting screws and anchors (included)
❑ 2 antennas (included)
❑ 4-conductor, 22-gauge or larger, stranded wire
❑ Support standoff (included with Concord cabinet)
❑ ¼-inch press-fit reed switch and magnet (not included)
❑ Small hammer
Installation
The module can be mounted inside the panel cabinet or on
any interior wall (protected from the elements).
CAUTION
To prevent damaging the panel or module, remove the
panel AC power transformer and disconnect the
backup battery before installation.
CAUTION
You must be free of static electricity before handling
circuit boards. Wear a grounding strap or touch a bare
metal surface to discharge static electricity.
Figure 3. Removing the Cover
To mount the module on a wall:
1. Remove the panel AC power transformer and discon-
nect the backup battery.
2. Remove the module cover and set it aside (Figure 3).
3. Hold the base against the mounting surface and mark
the three mounting holes (Figure 1). Remember to
leave at least 10 inches
above the base for the
antennas.
4. Drill holes and insert the appropriate anchors.
5. Secure the back-plate to the wall with included pan-
head screws.
To mount the module in a Concord panel cabinet:
1. Remove the panel AC power transformer and discon-
nect the backup battery.
2. Remove and discard the module cover (Figure 3).
Table 2. Maximum Module Wire Lengths
Wire Gauge
(Unshielded
or Shielded)
Max. Wire Length Between
Module and Concord Panel
18 2,800 feet
22 1,100 feet
METAL
METAL
8836G02A.DS4
PRESS DOWN
HERE AND PULL
AWAY FROM BASE
8543118A.DSF