Service manual

Table Of Contents
2AV/X
2-4-1
2-4
Timing chart No. 1 From the main switch turned on to machine stabilization
MSW
FH
PM
DM
DB REM
CFM1,2,3
CN3-4
CN3-3
CN20-3,4,5
CN12-16
CN4-4
CN11-5,8,11
MSW: ON
1500 ms
1000 ms
Half speed Full speed Half speed
30 s20 s
Primary stabilization
fixing temperature
135°C/275°F
Secondary stabilization
fixing temperature
160°C/320°F