Service manual

Table Of Contents
2AV/X
1-6-33
1-6
15 cpm
Enter maintenance mode.
Enter 065 using the numeric keys.
Yes
No
Start
End
Press the interrupt key.
Place an original and press
the start key to make a test copy.
Is the image correct?
Setting range: 25 +25
Initial setting: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image wider, and decreasing it
makes the image narrower.
For copy example 1, increase the
value using the zoom (+) key.
For copy example 2, decrease the
value using the zoom () key.
Press the start key.
The new setting
is stored.
Select 1 (main scanning direction
using the copy exposure
adjustment keys).
Press the start key.
Press the stop/clear key to
exit maintenance mode.
Copy exposure adjustment keys
Setting 1 : Main scanning direction
2 : Auxiliary scanning direction
Original Copy
example
Copy
example 2
Figure 1-6-49b