Specifications
Shut off power.
Install the mounting strap as shown using two screws that fit your juntion box.
Route the light control`s wire and fixture wires as shown.Secure with wire connectors.
Note: L should be connected with the Black, N should be connected with White.
Installations advice:
As the detector responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors
etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning units,
light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
This product in intend for use with the enclosed gasket and with a junction box marked for use
in wet locations.
When the air temperature is close to a person’s body heat, the detection sensitivity will
reduce.
This light requires a 120-Volt AC power source.
Turn power off and test that power is off before installing the sensor.
Install the height of the light fixture not lower than 1.8m, to avoid disturbance from small
animals on the ground within detection range.
Warning. Danger of death through electric shock!
Must be installed by professional electrician.
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
Maintenance:
Care and Cleaning
To prolong the original appearance, suggest to clean the light fixture with clear water and
a soft, damp cloth.
Do not use paints, solvents, or other chemicals on this sensor. They could cause a
premature deterioration and damage to the finish. This is not a defect in the finish and will
not be covered by the warranty.
Do not spray the sensor with a hose or power washer.
Trouble shooting
5.2.1 The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
5.2.2 The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
5.2.3 The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power corresponds to the instruction