Technical information

Page 93
Wire Free Product Range
Controllers
Introduction
Wire free fire system technology is fast becoming
a recognised and accepted alternative to wired
fire alarm systems. Tyco Safety Products Radio
Fire Alarm System provides a level of performance
and reliability comparable to hard-wired systems.
It also has the added advantage of being totally
flexible, quick and easy to install with virtually no
damage or disruption.
This enables the installation of a fire alarm system
to be carried out in an occupied building where
cabling is unacceptable, unwelcome, disruptive or
impracticable. The cost of “making good” and
redecorating is significantly reduced with wire free
systems.
Radio Systems are highly cost effective and can
easily be modified or extended to combine with
existing hard wired systems. A system can be
tailored for use in any existing building to meet
highly individual needs for many commercial and
industrial applications. Regarding fire detection,
the radio system can be considered to be
identical to a hard-wired system, with the fire
survey carried out to the same standards.
The Radio Survey
It is important that a radio survey is carried out by
trained personnel on all sites, before a complete
system quotation can be made.
Features
• Detectors fire tested to prEN54 part 7
Designed to meet BS5839 Part 4
• Minimum Installation damage and disruption
• Flexible system design up to 96 zones
• System easily modified or extended
• 80 character LCD pinpoints each alarm with
plain text location messages
• Full zonal LED display and detailed fault
annunciation.
• Suitable for permanent or temporary
applications.
1000 Event memory
Up to 27 repeater panels
Long battery life
Typical Applications
• Heritage and Listed Buildings
• Art Galleries and Museums
• Schools and Colleges
• Hospitals, Clinics and Nursing Homes
• Temporary Systems for Refurbishments
• Airports and Military Bases
• Government and Council Buildings
• Exhibition Complexes and Stadia.
Note: The system elements and associated
product codes described in the Wire Free section
relate to the UK frequency variants as approved
by the Home Office for use in “low powered”
systems in the UK. 173 MHz (field devices) and
459 MHz (battery powered sounders). These
frequencies may be suitable for applications in
other countries. Please contact Tyco Safety
Products for further information.
The System 5000 FIRE POINT is designed using
EMS radio technology allowing flexibility and
expansion of wire-free fire detection systems. The
controller’s features have been targeted, but are
not exclusive to, a 4-zone panel system but with
the added benefits given by wire-free installation.
The fire alarm control panel incorporates state of
the art radio technology coupled with the features
required providing the user with a cost effective
and practical fire alarm panel.
The System 5000 FIREPOINT uses approved
industry standard devices such as callpoints,
sounders and Ziton detectors etc.
The addressable detector is alkaline battery
powered with a 5 year typical life cycle including
call points and sounders.
The panel technology is designed to meet the
requirements of the BS5839 and EN54 standards
and has been fully tested by the DTI to satisfy the
requirements of MPT 1305 and 1328 radio
standards. VHF technology for receiving
information from devices is combined with UHF
(at 500mW) for command signals to radio
sounders and personal pagers.
Technical Specification
Dimensions: 330 x 450 x 116mm
Power Requirements: 220/240V, 50Hz
Product Codes
Networked Versions
517.131.011
96 zone analogue addressable radio LAN
controller, VHF receiver , UHF transmitter, 252
device capacity c/w keypad and VFD display. 2
hardwire sounder circuits. RS232 and RS458
ports. BS5839 and EN54 Standard. C/W 2 Helical
Antennas and Thermal Printer.
517.131.012
24 zone analogue addressable radio LAN
controller with printer option, VHF receiver, UHF
transmitter, 252 device capacity c/w keypad and
LCD display with option for VFD display. 2
hardwire sounder circuits. RS232 and RS 485
ports. c/w 2 helical antennas.
517.131.013
24 zone analogue addressable radio LAN
controller, VHF receiver, UHF transmitter, 252
device capacity c/w keypad and LCD display with
option for VFD display. 2 hardwire sounder
circuits. RS232 and RS485 ports. Comes with
2 x helical antennas and thermal printer.
517.131.014
12 zone LAN analogue addressable controller
with printer option, VHF receiver, UHF transmitter,
252 device capacity c/w keypad and LCD display.
2 hardwire sounder circuits. RS232 and RS485
ports. c/w 2 helical antennas.
517.131.015
12 zone radio LAN analogue addressable
controller with panel mounted event printer, VHF
receiver, UHF transmitter, 252 device capacity c/w
keypad and LCD display. 2 hardwire sounder
circuits.RS232 and RS485 ports. Comes with 2 x
helical antennas and thermal printer.
517.131.016
4 zone radio LAN addressable controller, VHF
receiver, UHF transmitter, 252 device capacity c/w
keypad and LCD display. 2 hardwire sounder
circuits. RS232 and RS485 ports. Supplied c/w 2
helical antennas.
Stand Alone Versions
517.131.001
24 zone analogue addressable controller, VHF
receiver, UHF transmitter, 252 device capacity c/w
keypad and VDF display. 2 hardwire sounder
circuits. RS232 and RS485 ports. BS5839 and
EN 54 Standard. Supplied c/w 2 helical antennas
(Not inc. Batteries).
517.131.002
12 zone analogue addressable controller, VHF
receiver, UHF transmitter, 252 device capacity c/w
keypad and VFD display. 2 hardwire sounder
circuits. RS232 and RS 485 ports. BS5839 and
EN54 Standard. Supplied c/w 2 helical antennas
(Not inc. Batteries).
517.131.017
96 zone analogue addressable controller with
panel mounted printer, VHF receiver, UHF
transmitter, 252 device capacity c/w keypad and
VFD display. 2 hardwire sounder circuits. RS232
and RS485 ports. c/w 2 helical antennas.
517.131.018
24 zone analogue addressable controller with
panel mounted printer, VHF receiver, UHF
transmitter, 252 device capacity c/w keypad and
LCD display with option for VFD display. 2
hardwire sounder circuits. RS232 and RS485
ports. Supplied c/w 2 helical antennas.
517.131.019
4 Zone Addressable Control Panel VHF receiver,
UHF transmitter, 252 device capacity c/w keypad
and LCD display. 2 hardwire sounder circuits.
RS232 and RS485 ports. BS5839 and EN 54
Standard. Supplied c/w 2 helical antennas